7.OTHERS PROBLEMS

The machine is not turned on, or the LED indication does not appear.

Step

Cause

Check

Result

Remedy

 

 

 

 

 

 

Harness

Is the harness of the

 

Reconnect the panel PCB

1

connection

panel PCB ASSY

No

ASSY harness.

failure of panel

connected correctly?

 

 

 

 

 

PCB

 

 

 

 

 

 

 

 

 

Panel PCB

Is the problem solved

 

Replace the panel PCB

2

failure

after replacing the panel

Yes

ASSY.

 

 

PCB ASSY?

 

 

 

 

 

 

 

 

LVPS PCB failure

Is the problem solved

 

Replace the PS PCB unit.

3

 

after replacing the PS

Yes

 

 

 

PCB unit?

 

 

 

 

 

 

 

 

Main PCB failure

Is the problem solved

 

Replace the main PCB

4

 

after replacing the main

Yes

ASSY.

 

 

PCB ASSY?

 

 

 

 

 

 

 

The fan does not work.

Step

Cause

Check

Result

Remedy

 

 

 

 

 

 

Harness

Is the harness of the fan

 

Reconnect the harness of

1

connection

motor 60 ASSY

No

the fan motor 60 ASSY

failure of the fan

connected correctly?

correctly.

 

 

 

motor 60 ASSY.

 

 

 

 

 

 

 

 

 

Toner sensor

Is the problem solved

 

Replace the toner sensor

2

PCB failure

after replacing the toner

Yes

PCB ASSY.

 

 

sensor PCB ASSY?

 

 

 

 

 

 

 

 

Main PCB failure

Is the problem solved

 

Replace the main PCB

3

 

after replacing the main

Yes

ASSY.

 

 

PCB ASSY?

 

 

 

 

 

 

 

1-37