15)Laser unit failure

Laser diode failure

 

Step

Cause

Remedy

 

 

 

 

 

 

 

 

 

1

Laser unit harness connection

Check the two harness connections of the

 

failure

laser unit and reconnect them.

 

 

 

 

 

 

 

 

FG harness ASSY connection

Check the FG harness ASSY connection

 

2

failure

between the laser unit and main PCB

 

 

 

ASSY. Then reconnect it.

 

 

 

 

 

3

Laser unit failure

Replace the laser unit.

 

 

 

 

 

4

Main PCB failure

Replace the main PCB ASSY.

 

 

 

 

16)

Main motor failure

 

 

 

 

 

 

Step

Cause

Remedy

 

 

 

 

 

1

Main motor harness connection

Check the harness connection of the main

 

failure

motor and reconnect it.

 

 

 

 

 

 

 

2

Main motor failure

Replace the drive sub ASSY.

 

 

 

 

 

3

Low-voltage power supply PCB

Replace the PS PCB unit.

 

failure

 

 

 

 

 

 

 

 

 

4

Main PCB failure

Replace the main PCB ASSY.

 

 

 

 

17)

High-voltage power supply PCB failure

 

 

 

 

 

 

Step

Cause

Remedy

 

 

 

 

 

 

 

 

 

 

High-voltage power supply PCB

Check the harness connection between the

 

1

ASSY harness connection failure

high-voltage power supply PCB and main

 

 

 

PCB. Then reconnect it.

 

 

 

 

 

2

High-voltage power supply PCB

Replace the high-voltage power supply

 

failure

PCB ASSY.

 

 

 

 

 

 

 

3

Low-voltage power supply PCB

Replace the PS PCB unit.

 

failure

 

 

 

 

 

 

 

 

 

4

Main PCB failure

Replace the main PCB ASSY.

 

 

 

 

18)Fan failure

 

 

 

 

 

 

Step

Cause

Remedy

 

 

 

 

 

1

Fan harness connection failure

Check the harness connection of the fan

 

 

motor 60 unit, and reconnect it.

 

 

 

 

 

 

 

 

2

Fan failure

Replace the fan motor 60 unit.

 

 

 

 

 

3

Toner sensor PCB failure

Replace the toner sensor PCB

 

 

 

 

 

4

Main PCB failure

Replace the main PCB ASSY.

 

 

 

 

1-16

Confidential