Memory full
User Check
•Print the stored data.
•Reduce the data capacity or reduce the print resolution.
12)Print overrunData expansion is not in time
User Check
•Press the [Go] button, then print the stored data.
•Reduce the complexity of data or reduce the print resolution.
13)Main PCB failureUser Check
• Turn the power off and on.
Step | Cause | Remedy |
|
|
|
|
|
|
1 | Main PCB failure | Replace the main PCB ASSY. |
|
|
|
Step | Cause | Remedy |
|
|
|
|
|
|
| Harness connection failure | Check the harness connection between |
1 | between fuser unit connector and | fuser unit connector and eject sensor PCB |
| eject sensor PCB ASSY | ASSY. |
|
|
|
2 | Fuser unit failure | Replace fuser unit. |
|
|
|
3 | Replace the PS PCB unit. | |
failure |
| |
|
| |
|
|
|
4 | Toner LED PCB failure | Replace the toner LED PCB ASSY. |
|
|
|
5 | Main PCB failure | Replace the main PCB ASSY. |
|
|
|
CAUTION:
This problem will be cleared if leaving the machine power ON for ten minutes.
Turn the power on while pressing the SW supporter, when the front cover is open. And check that Toner, Drum and Error LEDs light up, and then release the SW supporter.
Check that all LEDs go off and press the SW supporter once, and then this problem may be cleared by that press the SW supporter once again after all LEDs light up.
Confidential |