8)Front cover is open

Front cover opened

User Check

Check if the front cover is closed certainly.

Step

Cause

Remedy

 

 

 

 

 

 

 

Cover sensor harness ASSY

Check the sensor performance following

1

failure

the procedure in "Factory Inspection Mode"

 

(Chapter 5). If any problem occurs, replace

 

 

 

 

the Cover sensor harness ASSY.

 

 

 

2

Harness connection failure of

Check the harness connection of the Cover

Cover sensor harness ASSY

sensor harness ASSY and reconnect it.

 

 

 

 

 

Part pressing the Cover sensor

Replace the front cover ASSY.

3

harness ASSY is broken, which is

 

 

provided at inside of front cover

 

 

 

 

4

Toner LED PCB ASSY failure

Replace the toner LED PCB ASSY.

 

 

 

5

Main PCB ASSY failure

Replace the main PCB ASSY.

 

 

 

9)Fuser cover is open

Fuser cover opened

User Check

Check if the fuser cover is closed certainly.

Step

Cause

Remedy

 

 

 

 

 

 

1

Paper eject actuator catching on

Correct catching of the paper eject

some position

actuator.

 

 

 

 

2

Paper eject actuator failure

Replace the paper eject actuator.

 

 

 

3

Eject sensor PCB ASSY failure

Replace the eject sensor PCB ASSY.

 

 

 

4

Main PCB ASSY failure

Replace the main PCB ASSY.

 

 

 

1-12

Confidential