Front cover opened
User Check
•Check if the front cover is closed certainly.
Step | Cause | Remedy | |
|
|
| |
|
|
| |
| Cover sensor harness ASSY | Check the sensor performance following | |
1 | failure | the procedure in "Factory Inspection Mode" | |
| (Chapter 5). If any problem occurs, replace | ||
|
| ||
|
| the Cover sensor harness ASSY. | |
|
|
| |
2 | Harness connection failure of | Check the harness connection of the Cover | |
Cover sensor harness ASSY | sensor harness ASSY and reconnect it. | ||
| |||
|
|
| |
| Part pressing the Cover sensor | Replace the front cover ASSY. | |
3 | harness ASSY is broken, which is |
| |
| provided at inside of front cover |
| |
|
|
| |
4 | Toner LED PCB ASSY failure | Replace the toner LED PCB ASSY. | |
|
|
| |
5 | Main PCB ASSY failure | Replace the main PCB ASSY. | |
|
|
|
Fuser cover opened
User Check
•Check if the fuser cover is closed certainly.
Step | Cause | Remedy | |
|
|
| |
|
|
| |
1 | Paper eject actuator catching on | Correct catching of the paper eject | |
some position | actuator. | ||
| |||
|
|
| |
2 | Paper eject actuator failure | Replace the paper eject actuator. | |
|
|
| |
3 | Eject sensor PCB ASSY failure | Replace the eject sensor PCB ASSY. | |
|
|
| |
4 | Main PCB ASSY failure | Replace the main PCB ASSY. | |
|
|
|
Confidential |