3.PAPER FEEDING PROBLEMS
Problems related to paper feeding are end user recoverable if following the User Check items. If the same problem occurs again, follow each procedure in the order of the number described in the Step column in the tables below.
3.1No Feeding
Step | Cause | Check | Result | Remedy |
|
|
|
|
|
|
|
|
|
|
| Edge actuator | Does the edge actuator |
| |
1 | catching on some | move smoothly? | No | actuator |
| position |
|
|
|
|
|
|
|
|
| Roller holder | Does the roller holder |
| |
2 | ASSY catching on | ASSY move smoothly? | Yes | holder ASSY. |
| some position |
|
|
|
|
|
|
|
|
| Registration front | Is the problem solved |
| Replace the registration |
3 | sensor failure | after replacing the | Yes | front sensor PCB ASSY. |
| registration front sensor |
| ||
|
|
|
| |
|
| PCB ASSY? |
|
|
|
|
|
|
|
| Paper feeding kit | Is the surface of the |
| 1) Clean the surface of |
| failure | separation pad or the |
| the separation pad or |
4 |
| pickup roller dirty or worn | Yes | pickup roller. |
|
| out? |
| 2) Replace the separation |
|
|
|
| pad or pickup roller. |
|
|
|
|
|
5 | Pressure plate | Is the pressure plate gear | Yes | Replace the paper tray. |
gear damage | damaged? |
| ||
|
|
| ||
|
|
|
|
|
6 | T1 solenoid failure | Does the T1 solenoid | No | Replace the T1 solenoid |
| work correctly? |
| ||
|
|
|
| |
|
|
|
|
|
| T1 solenoid | Is the problem solved |
| Replace the |
| pathway of the | after replacing the high- |
| power supply PCB ASSY. |
7 | voltage power supply | Yes |
| |
| power supply PCB | PCB ASSY? |
|
|
| broken |
|
|
|
|
|
|
|
|
| Main PCB failure | Is the problem solved |
| Replace the main PCB |
8 |
| after replacing the main | Yes | ASSY. |
|
| PCB ASSY? |
|
|
|
|
|
|
|
| Main motor failure | Is the problem solved |
| Replace the drive sub |
9 |
| after replacing the drive | Yes | ASSY. |
|
| sub ASSY? |
|
|
|
|
|
|
|
3.2Double Feeding
Step | Cause | Check | Result | Remedy | |
|
|
|
|
| |
|
|
|
|
| |
1 | Paper feeding kit | Is the surface of the | Yes | Replace the paper | |
failure | separation pad worn out? | feeding kit. | |||
|
| ||||
|
|
|
|
|
Confidential |