Table 14 — Fan Performance 580F048 — Vertical Discharge Units, Alternate Motor (Belt Drive)*

AIRFLOW

 

 

 

 

 

EXTERNAL STATIC PRESSURE (in. wg)

 

 

 

 

 

 

0.2

 

 

0.4

 

 

0.6

 

 

0.8

 

 

1.0

 

(Cfm)

 

 

 

 

 

 

 

 

 

 

 

Rpm

Bhp

Watts

Rpm

Bhp

Watts

Rpm

Bhp

Watts

Rpm

Bhp

Watts

Rpm

Bhp

Watts

1200

666

0.26

257

778

0.37

367

871

0.47

471

952

0.57

572

1025

0.67

670

1300

701

0.31

306

810

0.43

426

901

0.54

540

981

0.65

651

1053

0.76

760

1400

737

0.36

361

842

0.49

491

931

0.62

616

1010

0.74

738

1081

0.86

856

1500

773

0.42

422

875

0.57

564

963

0.70

699

1040

0.84

831

1110

0.96

960

1600

810

0.49

491

909

0.65

643

994

0.79

790

1070

0.94

932

1140

1.08

1070

1700

847

0.57

567

943

0.73

730

1027

0.89

888

1101

1.05

1040

1170

1.20

1189

1800

885

0.66

652

978

0.83

826

1060

1.00

994

1133

1.16

1157

1900

923

0.75

745

1014

0.94

930

1093

1.11

1109

2000

962

0.85

847

1049

1.05

1043

 

 

 

 

 

 

 

 

 

 

 

 

AIRFLOW

 

 

 

 

 

EXTERNAL STATIC PRESSURE (in. wg)

 

 

 

 

 

 

1.2

 

 

1.4

 

 

1.6

 

 

1.8

 

 

2.0

 

(Cfm)

 

 

 

 

 

 

 

 

 

 

 

Rpm

Bhp

Watts

Rpm

Bhp

Watts

Rpm

Bhp

Watts

Rpm

Bhp

Watts

Rpm

Bhp

Watts

1200

1093

0.77

767

1155

0.87

861

1213

0.96

955

1268

1.05

1047

1321

1.14

1137

1300

1119

0.87

866

1181

0.98

970

1239

1.08

1073

1294

1.18

1175

1400

1147

0.98

972

1208

1.09

1086

1500

1175

1.09

1086

1600

1700

1800

1900

2000

LEGEND

Bhp — Brake Horsepower Input to Fan

Watts — Input Watts to Motor

*Motor drive range: 770 to 1175 rpm. All other rpms require a field- supplied drive.

NOTES:

1.Boldface indicates field-supplied drive is required.

2.Maximum continuous bhp is 1.20.

3.See page 36 for general fan performance notes.

Table 15 — Fan Performance 580F048 — Vertical Discharge Units, High-Static Motor (Belt Drive)*

AIRFLOW

 

 

 

 

 

EXTERNAL STATIC PRESSURE (in. wg)

 

 

 

 

 

 

0.2

 

 

0.4

 

 

0.6

 

 

0.8

 

 

1.0

 

(Cfm)

 

 

 

 

 

 

 

 

 

 

 

Rpm

Bhp

Watts

Rpm

Bhp

Watts

Rpm

Bhp

Watts

Rpm

Bhp

Watts

Rpm

Bhp

Watts

1200

666

0.26

257

778

0.37

367

871

0.47

471

952

0.57

572

1025

0.67

670

1300

701

0.31

306

810

0.43

426

901

0.54

540

981

0.65

651

1053

0.76

760

1400

737

0.36

361

842

0.49

491

931

0.62

616

1010

0.74

738

1081

0.86

856

1500

773

0.42

422

875

0.57

564

963

0.70

699

1040

0.84

831

1110

0.96

960

1600

810

0.49

491

909

0.65

643

994

0.79

790

1070

0.94

932

1140

1.08

1070

1700

847

0.57

567

943

0.73

730

1027

0.89

888

1101

1.05

1040

1170

1.20

1189

1800

885

0.66

652

978

0.83

826

1060

1.00

994

1133

1.16

1157

1200

1.32

1316

1900

923

0.75

745

1014

0.94

930

1093

1.11

1109

1165

1.29

1283

1231

1.46

1453

2000

962

0.85

847

1049

1.05

1043

1127

1.24

1233

1198

1.42

1417

1263

1.61

1598

 

 

 

 

 

 

 

 

 

 

 

 

AIRFLOW

 

 

 

 

 

EXTERNAL STATIC PRESSURE (in. wg)

 

 

 

 

 

 

1.2

 

 

1.4

 

 

1.6

 

 

1.8

 

 

2.0

 

(Cfm)

 

 

 

 

 

 

 

 

 

 

 

Rpm

Bhp

Watts

Rpm

Bhp

Watts

Rpm

Bhp

Watts

Rpm

Bhp

Watts

Rpm

Bhp

Watts

1200

1093

0.77

767

1155

0.87

861

1213

0.96

955

1268

1.05

1047

1321

1.14

1137

1300

1119

0.87

866

1181

0.98

970

1239

1.08

1073

1294

1.18

1175

1346

1.28

1275

1400

1147

0.98

972

1208

1.09

1086

1265

1.21

1199

1320

1.32

1310

1371

1.43

1419

1500

1175

1.09

1086

1235

1.22

1209

1292

1.34

1332

1346

1.46

1452

1397

1.58

1572

1600

1204

1.21

1207

1263

1.35

1340

1320

1.48

1472

1373

1.61

1603

1424

1.74

1732

1700

1233

1.34

1336

1292

1.49

1480

1348

1.63

1622

1401

1.77

1762

1451

1.91

1901

1800

1262

1.48

1473

1321

1.64

1627

1376

1.79

1779

1428

1.94

1930

1479

2.09

2078

1900

1293

1.63

1620

1350

1.79

1784

1405

1.96

1946

1457

2.12

2106

1506

2.28

2265

2000

1323

1.79

1776

1380

1.96

1950

1434

2.13

2123

1486

2.31

2293

LEGEND

Bhp — Brake Horsepower Input to Fan

Watts — Input Watts to Motor

*Motor drive range: 1075 to 1455 rpm. All other rpms require a field-supplied drive.

NOTES:

1.Boldface indicates field-supplied drive is required.

2.Maximum continuous bhp is 2.40.

3.See page 36 for general fan performance notes.

27

Page 27
Image 27
Bryant 580F External Static Pressure in. wg Cfm Rpm Bhp Watts, 955, 1181 970, 1073, 1208 1086, 778 367 871 471 952 572

580F specifications

The Bryant 580F is a highly regarded gas furnace known for its exceptional heating performance and advanced technology. Designed for residential use, this model stands out for its reliability, efficiency, and user-friendly features that cater to modern heating demands.

One of the most notable features of the Bryant 580F is its efficiency rating. With an AFUE (Annual Fuel Utilization Efficiency) rating of up to 95%, this furnace maximizes heat output while minimizing energy consumption. This high level of efficiency not only results in lower utility bills but also reduces the environmental impact—a critical consideration for today’s eco-conscious homeowners.

The Bryant 580F is equipped with a multi-speed blower that ensures consistent airflow and enhances comfort by maintaining even temperatures throughout the home. This technology allows the furnace to adjust its operation based on the heating needs, leading to quieter operation and increased comfort levels.

In terms of construction, the Bryant 580F is built with durable materials that promise longevity and resilience against wear and tear. Its compact design makes installation easier, allowing it to fit into tight spaces without compromising its performance.

One of the standout technologies integrated into the Bryant 580F is its enhanced control system. The furnace works seamlessly with smart thermostats, allowing homeowners to monitor and adjust heating settings from their mobile devices. This feature not only provides convenience but also allows for energy-saving optimizations based on personal schedules and preferences.

Safety is also a primary concern with the Bryant 580F. It includes robust safety features such as a hot surface ignition system that eliminates the need for a standing pilot light, reducing the risk of gas leaks. Additionally, advanced diagnostics help in troubleshooting and maintenance, ensuring that potential issues can be identified and resolved quickly.

In conclusion, the Bryant 580F gas furnace is a remarkable choice for those seeking a blend of efficiency, comfort, and advanced technology. Its high AFUE rating, multi-speed blower, smart control compatibility, and safety features make it a reliable option for homeowners looking to invest in a dependable heating solution. As the demand for energy-efficient heating continues to grow, the Bryant 580F stands out as a model that meets and exceeds expectations in the modern heating landscape.