Bryant 580F installation instructions Physical Data

Models: 580F

1 64
Download 64 pages 4.35 Kb
Page 8
Image 8

Table 1 — Physical Data

UNIT SIZE 580F

 

036

 

 

048

 

060

 

 

072

 

 

073

NOMINAL CAPACITY (tons)

 

3

 

 

4

 

5

 

 

6

 

 

6

 

OPERATING WEIGHT (lb)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Unit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Al/Al*

 

460

 

 

470

 

490

 

 

565

 

 

615

Al/Cu*

 

465

 

 

476

 

497

 

 

576

 

 

Cu/Cu*

 

468

 

 

482

 

505

 

 

587

 

 

Economizer

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EconoMi$er+

 

50

 

 

50

 

50

 

 

50

 

 

50

Roof Curb†

 

115

 

 

115

 

115

 

 

115

 

 

115

COMPRESSOR

 

 

 

 

 

Reciprocating

 

 

 

 

 

 

Scroll

 

 

Quantity

 

1

 

 

1

 

1

 

 

1

 

 

1

 

 

 

 

 

 

No. Cylinders (per Circuit)

 

2

 

 

2

 

2

 

 

2

 

 

2

 

Oil (oz)

 

50

 

 

50

 

50

 

 

54

 

 

60

REFRIGERANT TYPE

 

 

 

 

 

 

 

 

R-22

 

 

 

 

 

 

Expansion Device

 

 

 

 

 

 

Fixed Orifice Metering Device

 

 

 

 

 

 

Operating Charge (lb-oz)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Circuit 1

 

4-4

 

 

6-6

 

6-14

 

 

9-0

 

 

11-0

Circuit 2

 

 

 

 

 

 

 

 

CONDENSER COIL

 

 

 

 

 

Enhanced Copper Tubes, Aluminum Lanced Fins

 

 

Rows...Fins/in.

 

1...17

 

 

2...17

 

2...17

 

 

2...17

 

 

2...17

 

 

 

 

 

Total Face Area (sq ft)

 

8.36

 

 

8.36

 

10.42

 

 

10.42

 

 

16.5

CONDENSER FAN

 

 

 

 

 

 

 

 

Propeller Type

 

 

 

 

 

 

Nominal Cfm

 

3500

 

 

4000

 

4000

 

 

4000

 

 

4100

 

 

 

 

 

Quantity...Diameter (in.)

 

1...22.0

 

 

1...22.0

 

1...22.0

 

 

1...22.0

 

 

1...22.0

Motor Hp...Rpm

 

1/ ...1100

 

 

1/ ...1100

 

1/ ...1100

 

 

1/ ...1100

 

 

1/ ...1100

Watts Input (Total)

 

4

 

 

 

4

 

 

4

 

 

 

4

 

 

 

4

 

 

325

 

 

325

 

325

 

 

325

 

 

320

EVAPORATOR COIL

 

 

 

Enhanced Copper Tubes, Aluminum Double-Wavy Fins

 

 

Rows...Fins/in.

 

2...15

 

 

2...15

 

3...15

 

 

4...15

 

 

4...15

 

 

 

 

 

Total Face Area (sq ft)

 

4.17

 

 

5.5

 

5.5

 

 

5.5

 

 

5.5

EVAPORATOR FAN

 

 

 

 

 

 

 

Centrifugal Type

 

 

 

 

 

 

Quantity...Size (in.)

Std

1...10 x 10

 

 

1...10 x 10

 

1...11 x 10

 

 

1...10 x 10

 

 

1...10 x 10

 

 

 

 

 

 

Alt

1...10 x 10

 

 

1...10 x 10

 

1...10 x 10

 

 

 

 

 

High-Static

1...10 x 10

 

 

1...10 x 10

 

1...11 x 10

 

 

1...10 x 10

 

 

1...10 x 10

Type Drive

Std

Direct

 

 

Direct

 

Direct

 

 

Belt

 

 

Belt

 

Alt

Belt

 

 

Belt

 

Belt

 

 

 

 

Nominal Cfm

High-Static

Belt

 

 

Belt

 

Belt

 

 

Belt

 

 

Belt

 

1200

 

 

1600

 

2000

 

 

2100

 

 

2100

Maximum Continuous Bhp

Std

.34

 

 

.75

 

1.20

 

 

2.40

 

 

2.40

 

Alt

1.20

 

 

1.20

 

1.30/2.40**

 

 

 

 

 

High-Static

2.40

 

 

2.40

 

2.90

 

 

2.90

 

 

2.90

Motor Frame Size

Std

48

 

 

48

 

48

 

 

56

 

 

56

 

Alt

48

 

 

48

 

56

 

 

 

 

 

High-Static

56

 

 

56

 

56

 

 

56

 

 

56

Nominal Rpm High/Low (Direct Drive)

Std

860/800

 

 

1075/970

 

1075/970

 

 

 

 

 

Alt

 

 

 

 

 

 

 

 

High-Static

 

 

 

 

 

 

 

Fan Rpm Range

Std

 

 

 

 

 

1070-1460

 

 

1070-1460

 

Alt

685-1045

 

 

770-1175

 

8778-1192

 

 

 

 

Motor Bearing Type

High-Static

1075-1455

 

 

1075-1455

 

1300-1685

 

 

1300-1685

 

 

1300-1685

 

Ball

 

 

Ball

 

Ball

 

 

Ball

 

 

Ball

Maximum Allowable Rpm

 

2100

 

 

2100

 

2100

 

 

2100

 

 

2100

Motor Pulley Pitch Diameter Min/Max (in.)

Std

 

 

 

 

 

2.8/3.8

 

 

2.8/3.8

 

Alt

1.9/2.9

 

 

1.9/2.9

 

2.4/3.4

 

 

 

 

 

High-Static

2.8/3.8

 

 

2.8/3.8

 

3.4/4.4

 

 

3.4/4.4

 

 

3.4/4.4

Nominal Motor Shaft Diameter (in.)

Std

1/

2

 

 

1/

2

 

1/

2

 

 

5/

8

 

 

5/

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8

 

Alt

1/2

 

 

1/2

 

5/8

 

 

 

 

 

High-Static

5/

8

 

 

5/

8

 

5/

8

 

 

5/

8

 

 

7/

 

Fan Pulley Pitch Diameter (in.)

Std

 

 

 

 

 

 

 

 

 

 

 

8

 

 

 

 

 

4.5

 

 

4.5

 

Alt

4.5

 

 

4.0

 

4.5

 

 

 

 

 

High-Static

4.5

 

 

4.5

 

4.5

 

 

4.5

 

 

4.5

Belt, Quantity...Type...Length (in.)

Std

 

 

 

 

 

1...A...40

 

 

1...A...40

 

Alt

1...A...34

 

 

1...A...34

 

1...A...39

 

 

 

 

 

High-Static

1...A...39

 

 

1...A...39

 

1...A...40

 

 

1...A...40

 

 

1...A...40

Pulley Center Line Distance (in.)

Std

 

 

 

 

 

14.7-15.5

 

 

14.7-15.5

 

Alt

10.0-12.4

 

 

10.0-12.4

 

14.7-15.5

 

 

 

 

 

High-Static

10.0-12.4

 

 

10.0-12.4

 

14.7-15.5

 

 

14.7-15.5

 

 

14.7-15.5

Speed Change per Full Turn of

Std

 

 

 

 

 

80

 

 

80

Movable Pulley Flange (rpm)

Alt

48

 

 

70

 

80

 

 

 

 

 

High-Static

65

 

 

65

 

60

 

 

60

 

 

60

Movable Pulley Maximum Full Turns

Std

 

 

 

 

 

5

 

 

5

 

From Closed Position

Alt

5

 

 

5

 

6

 

 

 

 

 

High-Static

6

 

 

6

 

5

 

 

5

 

 

5

 

Factory Setting

Std

 

 

 

 

 

3

 

 

3

 

 

Alt

3

 

 

3

 

3

 

 

 

 

 

High-Static

31/

 

 

31/

 

31/

 

 

31/

 

 

31/

2

Factory Speed Setting (rpm)

Std

 

2

 

 

 

2

 

 

2

 

 

 

2

 

 

 

 

 

 

 

 

1226

 

 

1226

 

Alt

829

 

 

932

 

1035

 

 

 

 

 

High-Static

1233

 

 

1233

 

1416

 

 

1416

 

 

1416

Fan Shaft Diameter at Pulley (in.)

 

5/

8

 

 

5/

8

 

5/

8

 

 

5/

8

 

 

5/

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8

 

 

LEGEND

Al

Aluminum

Bhp —

Brake Horsepower

Cu

Copper

*Evaporator coil fin material/condenser coil fin material. Contact your local rep- resentative for details about coated fins.

†Weight of 14-in. roof curb. **Single phase/three-phase.

††Rollout switch lockout is manually reset by interrupting power to unit or reset- ting thermostat.

California rated three-phase high heat models.

***Three phase standard high-heat models have heating input values as shown. Single phase standard high heat models have one-stage heating with heating input values as follows:

580FJV036115 — 115,000 Btuh

580FJV048150 — 150,000 Btuh

580FJV060150 — 150,000 Btuh

†††California SCAQMD compliant Low NOx models have combustion products that are controlled to 40 nanograms per joule or less.

8

Page 8
Image 8