Bunn TITAN DUAL manual BREW SETTINGS cont, Next, Press YES to proceed. The display should now

Models: TITAN DUAL

1 58
Download 58 pages 48.87 Kb
Page 21
Image 21
BREW SETTINGS (cont.)

PROGRAMMING THE BREWER (cont.)

PROGRAMMING FUNCTIONS - LEVEL 2 (cont.)

BREW SETTINGS (cont.)

Procedure to set or modify % Bypass settings. Range: 0 to 90% for both batch sizes

1.

Press and hold the right hidden button until display

 

reads SET LANGUAGE. Press the right hidden but-

 

ton until display reads BREW SETTINGS ?.

2.

Press YES to proceed. The display should now

BREW SETTINGS ?

NO YES

PRESSING NO WILL

LEFT SIDE

ADVANCE TO NEXT

 

FUNCTION SCREEN

MODIFY SHOW NEXT

 

read LEFT SIDE, along with MODIFY, SHOW and

NEXT.

3. Press and release the right hidden button until

display reads % BYPASS XXX.X. A batch light will be blinking.

4. Using (-)and (+), set the amount of bypass water (percentage) to be dispensed around the gounds for that particular batch size.

SET BOTH

BATCH SIZES

PRESS AND RELEASE

RIGHT HIDDEN SWITCH

UNTIL DISPLAY READS:

%BYPASS XXX.X (-) DONE (+)

5.When finished, press the other batch size and repeat step 4.

6.When finished setting both batch sizes, press DONE. The display should read 2 BATCHES DONE?

7.If both batch sizes are not correct, press NO to return to the % BYPASS: setup screen and repeat steps 4, 5 and 6.

8.If both batch sizes are correct, press YES. This will advance to L BREW METER. To exit to the MAIN SCREEN, press and release either ON/OFF button.

2 BATCHES DONE ?

NO YES

L BREW METER X

- I+

Page 21

40119 071107

 

Page 21
Image 21
Bunn TITAN DUAL manual BREW SETTINGS cont, PROGRAMMING THE BREWER cont PROGRAMMING FUNCTIONS - LEVEL 2 cont, Next