PROGRAMMING THE BREWER (cont.)
PROGRAMMING FUNCTIONS - LEVEL 2 (cont.)
BREW SETTINGS (cont.)
Procedure to set or modify % Bypass settings. Range: 0 to 90% for both batch sizes
1. | Press and hold the right hidden button until display |
| reads SET LANGUAGE. Press the right hidden but- |
| ton until display reads BREW SETTINGS ?. |
2. | Press YES to proceed. The display should now |
BREW SETTINGS ?
NO YES
PRESSING NO WILL | LEFT SIDE | |
ADVANCE TO NEXT | ||
| ||
FUNCTION SCREEN | MODIFY SHOW NEXT | |
|
read LEFT SIDE, along with MODIFY, SHOW and |
NEXT. |
3. Press and release the right hidden button until |
display reads % BYPASS XXX.X. A batch light will be blinking.
4. Using
SET BOTH
BATCH SIZES
PRESS AND RELEASE
RIGHT HIDDEN SWITCH
UNTIL DISPLAY READS:
%BYPASS XXX.X
5.When finished, press the other batch size and repeat step 4.
6.When finished setting both batch sizes, press DONE. The display should read 2 BATCHES DONE?
7.If both batch sizes are not correct, press NO to return to the % BYPASS: setup screen and repeat steps 4, 5 and 6.
8.If both batch sizes are correct, press YES. This will advance to L BREW METER. To exit to the MAIN SCREEN, press and release either ON/OFF button.
2 BATCHES DONE ?
NO YES
L BREW METER X
- I+
Page 21 | 40119 071107 |
|