PROGRAMMING THE BREWER (cont.)
PROGRAMMING FUNCTIONS - LEVEL 2 (cont.)
CALIBRATE FLOW
This function allows the operator to enter the actual flow rate of the sprayhead and the bypass for each side of the brewer by dispensing both separately for one minute. The volumes are then entered into the brewer.
Procedure to calibrate the sprayhead flow rate:
1.Place a container, accurately graduated and with a minimum capacity of 60 ounces, beneath the fun- nel.
2.Press and hold the right hidden button until the display reads SET LANGUAGE. Press the right hidden button until the display reads CALIBRATE FLOW.
3.Press and release YES to advance to the SPRAY HEAD CAL function screen. (Pressing NO in the CALIBRATE FLOW screen will advance to the next function screen, BREW COUNTERS).
4.Press and release the YES pad. The display should read CONTAINER READY? If the container is under the funnel, press YES.
5.The display should read CALIBRATE SPRAY. Press and release any BREW button on the side to be cali- brated to begin the sprayhead flow for calibration. The display should read CALIBRATE SPRAY...60 SEC TO FINISH. The
6.Measure the amount of water in the container and use the
7.The display should now read NEW L or NEW R SPRY FLOW, along with the correct flow rate of the sprayhead. After about 5 seconds, the display will return to the CALIBRATE FLOW screen.
8.Repeat steps 1-7 to calibrate the other side.
9.To exit the CALIBRATE FLOW function and advance to the next function screen, press and release NO. To exit programming, press and release either ON/OFF button to return to the MAIN SCREEN.
CALIBRATE FLOW?
NO YES
PRESSING NO WILL
ADVANCE TO
BREW COUNTERS
SPRAYHEAD CAL
NO YES
PRESSING NO WILL
ADVANCE TO
BREW COUNTERS
CONTAINER READY?
QUIT YES
CALIBRATE SPRAY
PRESS BREW START
CALIBRATE SPRAY 60 SEC TO FINISH
LEFT OZ XX.X
NEW L SPRY FLOW
XX.X OZM
5 sec
CALIBRATE FLOW?
NO YES
Page 30 | 40119 071107 |
|