PROGRAMMING THE BREWER (cont.)
PROGRAMMING FUNCTIONS - LEVEL 2 (cont.)
READY TEMP
This function allows the operator to set the minimum temperature allowable to start a brew cycle. The range can be from 2° to 20° F within the set temperature. The water must be at the READY temperature or higher for the display to indicate READY TO BREW. If brew lockout is enabled, the brewing process will not start below this READY temperature.
Procedure to set ready temperature
Range: 2° to 20° F (2° to 10° C)
1.Press and hold the right hidden button until display reads SET LANGUAGE. Press and release the right hidden button until display reads READY TEMP: XXX°.
2.Using (-) and (+), adjust the ready temperature.
3.When finished, press DONE to save the new setting and to advance to the next function screen, BREW SETTINGS ?. Press and release either ON/OFF but- ton to exit programming and return to the MAIN SCREEN.
READY TEMP: XXX° (-) DONE (+)
BREW SETTINGS ?
NO YES
Page 19 | 40119 071107 |
|