CALIBRATE FLOW (Continued)

PROGRAMMING THE BREWER (cont.)

PROGRAMMING FUNCTIONS - LEVEL 2 (cont.)

CALIBRATE FLOW (Continued)

Procedure to calibrate the bypass flow rate:

1.Place a container, accurately graduated and with a minimum capacity of 60 ounces, beneath the fun- nel.

2.Press and hold the right hidden button until the display reads SET LANGUAGE. Press the right hidden button until the display reads CALIBRATE FLOW.

3.Press and release YES to advance to the SPRAY HEAD CAL function screen. Press and release NO to advance to BYPASS CAL.

4.Press and release the YES pad. The display should read CONTAINER READY? If the container is under the funnel, press YES.

5.The display should read CALIBRATE BYPASS. Press and release any BREW button on the side to be calibrated to begin the flow for calibration. The display should read CALIBRATE BYPASS...60 SEC TO FINISH. The 60-second timer on the display will count down to zero. When the counter reaches zero, the display will changes to LEFT or RIGHT OZ/M, along with a number.

6.Measure the amount of water in the container and using the (-)and (+) pads, adjust the amount of the display to match the amount in the container. Then press DONE.

7.The display should now read NEW L or NEW R BYPS FLOW, along with the correct flow rate of the bypass. After about 5 seconds, the display will return to the CALIBRATE FLOW screen.

8.Repeat steps 1-7 to calibrate the other side.

9.To exit the CALIBRATE FLOW function and advance to the next function screen, press and release NO. To exit programming, press and release either ON/OFF button to return to the MAIN SCREEN.

CALIBRATE FLOW?

NO YES

PRESSING NO WILL

ADVANCE TO

BREW COUNTERS

SPRAYHEAD CAL

NO YES

BYPASS CAL?

QUIT YES

CONTAINER READY?

QUIT YES

CALIBRATE BYPASS

PRESS BREW START

CALIBRATE BYPASS 60 SEC TO FINISH

LEFT OZ XX.X (-) DONE (+)

NEW L BYPS FLOW

XX.X OZM

5 sec

CALIBRATE FLOW?

NO YES