PROGRAMMING THE BREWER (cont.)
PROGRAMMING FUNCTIONS - LEVEL 2 (cont.)
ENABLE ENERGYSAVR
This function allows the operator to enable the ENERGY SAVINGS mode function and set the idle time. Once the set idle time has expired, the operator can choose to have the heaters either turn off, or reduce the tank holding temp to 140° F (60° C).
Procedure to enable energy savings mode: Range: 0.5 to 24.0 hrs
If enabled, default setting is 140° F (60° C) tank tem- perature after 4.0 hrs. idle time.
1. | Press and hold the right hidden button until the dis- |
| play reads SET LANGUAGE. Press the right hidden |
| button until the display reads Enabl EnergySavr. |
| The YES or NO will be flashing to indicate the cur- |
| rent selection. |
2. | Press and release the NO button to disable this |
10.Once the idle time has expired, the display will read either ENERGY SAVER...NO TEMPERATURE or ENERGY SAVER...REDUCED TEMPERATURE, depending on the settings. This screen will alternate with PRESS ANY SWITCH TO
Enabl EnrgySavr
NO DONE YES
WITH YES FLASHING
PRESS DONE
| function, or: |
3. | Press and release the YES button to enable this |
| function (the heaters will either turn off or the tank |
| will hold at 140° F). |
4. | When finished, press and release DONE to save |
| the new setting and advance to the next function |
| screen. |
5. | If NO was selected, the display should now read |
| EnableFreshTimer. To exit programming and re- |
| turn to the MAIN SCREEN, press and release either |
| ON/OFF pad. |
WITH NO FLASHING
PRESS DONE TO
ADVANCE TO
ENABLEFRESHTIMER
X.X HRS
AFTER IDLE TIME? OFF DONE 140°
6. | If YES was selected, the display should now read |
| X.X HRS |
| to set the amount of time the brewer is not in use |
| before nap mode engages. Using |
| the idle time. When finished, press and release |
| DONE. |
7. | The display should now read AFTER IDLE TIME? |
| Once the set idle time has expired, the heaters can |
| either be shut off or held at a lower temperature of |
| 140° F. |
8. | To have the machine shut off after the set idle time, |
| press and release OFF and then DONE to save the |
| settings. The display should read MACHINE OFF |
| AFTER X.X HRS, and then EnableFreshTimer. |
9. | To have the heaters hold at the lower 140° F tem- |
| perature, press and release 140° and then DONE to |
| save the settings. The display should read MACHINE |
| AT 140° AFTER X.X HRS, and then EnableFresh- |
| Timer. |
MACHINE OFF | MACHINE AT 140° |
AFTER X.X HRS | AFTER X.X HRS |
EnableFreshTimer
NO DONE YES
40119 071107