Bunn TITAN DUAL Enable Energysavr, Procedure to enable energy savings mode Range 0.5 to 24.0 hrs

Models: TITAN DUAL

1 58
Download 58 pages 48.87 Kb
Page 36
Image 36
ENABLE ENERGYSAVR
Page 36

PROGRAMMING THE BREWER (cont.)

PROGRAMMING FUNCTIONS - LEVEL 2 (cont.)

ENABLE ENERGYSAVR

This function allows the operator to enable the ENERGY SAVINGS mode function and set the idle time. Once the set idle time has expired, the operator can choose to have the heaters either turn off, or reduce the tank holding temp to 140° F (60° C).

Procedure to enable energy savings mode: Range: 0.5 to 24.0 hrs

If enabled, default setting is 140° F (60° C) tank tem- perature after 4.0 hrs. idle time.

1.

Press and hold the right hidden button until the dis-

 

play reads SET LANGUAGE. Press the right hidden

 

button until the display reads Enabl EnergySavr.

 

The YES or NO will be flashing to indicate the cur-

 

rent selection.

2.

Press and release the NO button to disable this

10.Once the idle time has expired, the display will read either ENERGY SAVER...NO TEMPERATURE or ENERGY SAVER...REDUCED TEMPERATURE, depending on the settings. This screen will alternate with PRESS ANY SWITCH TO RE-HEAT.

Enabl EnrgySavr

NO DONE YES

WITH YES FLASHING

PRESS DONE

 

function, or:

3.

Press and release the YES button to enable this

 

function (the heaters will either turn off or the tank

 

will hold at 140° F).

4.

When finished, press and release DONE to save

 

the new setting and advance to the next function

 

screen.

5.

If NO was selected, the display should now read

 

EnableFreshTimer. To exit programming and re-

 

turn to the MAIN SCREEN, press and release either

 

ON/OFF pad.

WITH NO FLASHING

PRESS DONE TO

ADVANCE TO

ENABLEFRESHTIMER

X.X HRS -> IDLE (-) DONE (+)

AFTER IDLE TIME? OFF DONE 140°

6.

If YES was selected, the display should now read

 

X.X HRS -> IDLE. This screen allows the operator

 

to set the amount of time the brewer is not in use

 

before nap mode engages. Using (-)and (+), adjust

 

the idle time. When finished, press and release

 

DONE.

7.

The display should now read AFTER IDLE TIME?

 

Once the set idle time has expired, the heaters can

 

either be shut off or held at a lower temperature of

 

140° F.

8.

To have the machine shut off after the set idle time,

 

press and release OFF and then DONE to save the

 

settings. The display should read MACHINE OFF

 

AFTER X.X HRS, and then EnableFreshTimer.

9.

To have the heaters hold at the lower 140° F tem-

 

perature, press and release 140° and then DONE to

 

save the settings. The display should read MACHINE

 

AT 140° AFTER X.X HRS, and then EnableFresh-

 

Timer.

MACHINE OFF

MACHINE AT 140°

AFTER X.X HRS

AFTER X.X HRS

EnableFreshTimer

NO DONE YES

40119 071107

Page 36
Image 36
Bunn TITAN DUAL manual Enable Energysavr, Procedure to enable energy savings mode Range 0.5 to 24.0 hrs, Done, Timer