PROGRAMMING THE BREWER (cont.)
PROGRAMMING FUNCTIONS - LEVEL 2 (cont.)
BREW SETTINGS (cont.)
SET PULSE BREW/PREINFUSION
This function allows the operator to program the brewer to “pulse” the sprayhead flow on and off during a brew cycle (start and stop the flow of water out of the spray- head). This feature allows the ability to
INITIAL SPRAY | ON- | ON- |
| ON- |
TIME | TIME |
| TIME ALTERNATES UNTIL | |
|
| |||
|
|
|
| BREW CYCLE IS |
OFF- | OFF- |
| OFF- | COMPLETED |
|
| |||
TIME | TIME |
| TIME |
|
INITIAL SPRAY |
|
|
|
|
REMAINING ON |
|
|
| |
|
|
|
| |
|
|
| P2293 |
a)1st ON TIME – This time is the duration from when the brew button is pressed to when the desired water level in the funnel is reached. (Soaking the grounds)
b)
c)LAST
Setting Pulse Brew
Range: 1ST ON TIME – OFF to 4 minutes OFF TIME – OFF to 4 minutes
LAST ON TIME –
Setting Pulse Brew
1.Press and hold the right hidden button until display reads SET LANGUAGE. Press the right hidden but- ton until display reads BREW SETTINGS ?, along with NO and YES.
2.Press YES to proceed. The display should now read LEFT SIDE, along with MODIFY, SHOW and
NEXT.
3.Press and release the right hidden button until display reads SET PULSE BREW ?, along with NO and YES.
3.Press and release YES. The display should now read 1ST ON TIME X:XX. and a batch light will be blinking.
4.Using
5.When finished, press the other batch size and repeat step 4.
6.When finished setting both batch sizes, press DONE. The display will show the pulse settings to accommodate the brew time entered. Press each batch size to display the settings for that batch. If the 1ST ON TIME is set to OFF, the display will read PULSE BREW DISABLED. After a 5 second delay, the display will read 2 BATCHES DONE?.
7.If both batch sizes are not correct, press NO to return to the 1st ON TIME: setup screen and repeat steps 4, 5 and 6.
8.If both batch sizes are correct, press YES. This will advance to DRIP TIME. To exit to the MAIN SCREEN, press and release either ON/OFF button.
Page 23 | 40119 071107 |
|