TROUBLESHOOTING (cont.) |
|
|
|
|
|
PROBLEM |
| PROBABLE CAUSE |
| REMEDY | |
Dripping from sprayhead. |
| 1. Brew valve | Repair or replace leaky valve | ||
Water overflows filter. |
| 1. Type of paper filter | BUNN paper filters should be used | ||
|
|
|
|
| for proper extraction |
| 2. | No sprayhead | Check sprayhead | ||
Beverage overflows server. | 1. | Beverage left in server from | The brew cycle should be started | ||
|
| previous brew | only with an empty server under | ||
|
|
|
|
| the funnel. |
| 2. | Brew volume adjustment | Adjust the brew volume, calibrate | ||
|
|
|
|
| sprayhead and bypass as required |
|
|
|
|
| to achieve the desired volume for |
|
|
|
|
| each brew cycle |
Brewer is making unusual noises. |
| 1. Solenoids | The mounting screws on the so- | ||
|
|
|
|
| lenoids must be tight or they will |
|
|
|
|
| vibrate during operation |
| 2. | Plumbing lines | Plumbing lines should not be resting | ||
|
|
|
|
| on the countertop. |
| 3. | Water supply | The brewer must be connected to a | ||
|
|
|
|
| cold water line. Water pressure to |
|
|
|
|
| the brewer must not be higher than |
|
|
|
|
| 90 psi (620 kPa). Install a regulator |
|
|
|
|
| if necessary to lower the working |
|
|
|
|
| pressure to approximately 50 psi |
|
|
|
|
| (345 kPa). |
| 4. | Tank heaters | Remove and clean lime off tank | ||
|
|
|
|
| heaters. |
Page 55 | 40119 071107 |
|