PROGRAMMING THE BREWER (cont.)
PROGRAMMING FUNCTIONS - LEVEL 2 (cont.)
Procedure to test coil frequency:
1.Press and hold the right hidden button until the dis- play reads SET LANGUAGE. Press the right hidden button until the display reads SERVICE TOOLS.
2.Press and release YES. The display should now read TEST OUTPUTS? Press and release NO to advance to TEST SWITCHES.
3.Press and release NO to advance to TEST FRE-
QUENCY.
4.The display should now show the frequency of the sensor coil circuits. This is for diagnostic service use when troubleshooting this circuit.
5.After the coils have been tested, press and re- lease either ON/OFF button to return to the MAIN
SCREEN.
SERVICE TOOLS?
NO YES
PRESSING NO WILL
ADVANCE TO
FACTORY DEFAULTS
TEST OUTPUTS?
NO YES
TEST SWITCHES?
NO YES
TEST FREQUENCY?
NO YES
PRESSING NO WILL
ADVANCE TO
FACTORY DEFAULTS
4 125.0 Khz
Page 43 | 40119 071107 |
|