IP ROUTING NETWORK WITH REMOTE BRIDGE DEVICES

Verify the Installation

CONFIGURING THE OFF-NODE SERVER INFORMATION

The default configuration for Off-node Server Information is None (Use On-node). Since this network doesn’t require the use of an off-node server, no changes are necessary.

CONFIGURING THE NETWORK LOGIN INFORMATION

This network doesn’t require the use of a user level database so network login information configuration is not necessary.

SAVE CONFIGURATION FILES

We have now configured all necessary information. Press 4 from the Main menu to save the changes. The old configuration files will be stored in the \CONFIG directory with a file extension of .BAK (i.e., the old NODE.NEI file will be called NODE.BAK).

After you save the configuration files, press <RET> to exit the CFGEDIT program. Reboot the system to activate your changes.

VERIFY THE INSTALLATION

Steps on how to verify the installation are detailed in the System Verification chapter of the User’s Guide. This section gives an outline of which steps should be executed.

On the CyberSWITCH:

Verify hardware resources are operational

Issue dr command

Look for BRI line messages

Look for LAN initialized messages

Check for IP routing initialized message

Verify WAN Lines Available

Connect WAN lines

Issue dr command

Look for “Data Link up 1,1” in reports

On each Remote LAN:

Attempt to access a resource on the CyberSWITCH LAN. This may require that you reboot your system and proceed through the logon sequence.

Have the remote hosts ping the CyberSWITCH.

Have the CyberSWITCH ping the remote hosts (if a connection is up).

Workgroup Remote Access Switch 57