Troubleshooting

A.1.5 Check Firmware

To check whether or not the firmware is running correctly, issue the following command:

atmstat fa0 1

In this command, the last parameter “1”, causes the command to be repeated at one-second intervals.

If the firmware is running correctly, the response will show Input, Output, and Error Statistics for the adapter in the following format:

PHY/ATM/AAL statistics:

 

 

 

 

 

 

Output

 

Input

 

 

Errors

 

ATM

AAL*

ATM

AAL*

4B5B

4B5B

ATM

AAL*

AAL*

Cells

CS-PDUs

Cells

CS-PDUs Framing Hdr-CRC VPI/VCI Pay-CRC

Proto

161747

153692

142289

134685

0

0

20

0

0

If the firmware is not running correctly, atmstat hangs and nothing is returned, indicating either a problem with the firmware, a problem with the board, or a severe software failure. Call Cabletron Systems’ Technical Support for further assistance.

If the output shows zeros for all possible values, the firmware may not have been initialized. Try rebooting the system. If there is still a problem, call Cabletron Systems’ Technical Support for further assistance.