Carrier 50TCA04-A07 Phase, APPENDIX III. FAN PERFORMANCE cont, Ton Horizontal Supply, 50TC**04

Models: 50TCA04-A07

1 73
Download 73 pages 19.81 Kb
Page 56
Image 56
3 Phase

50TC

APPENDIX III. FAN PERFORMANCE (cont.)

50TC**04

3 Phase

3 Ton Horizontal Supply

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AVAILABLE EXTERNAL STATIC PRESSURE (IN. WG)

 

 

 

CFM

 

 

0.2

 

0.4

 

0.6

0.8

 

 

1.0

 

RPM

BHP

RPM

BHP

RPM

 

BHP

RPM

BHP

RPM

BHP

 

 

 

 

 

Field Supplied Drive1

 

Standard Static Option

Medium Static Option

900

 

554

0.14

681

0.22

783

0.32

870

0.42

947

0.53

975

 

575

0.16

701

0.25

801

0.35

888

0.45

965

0.57

1050

 

597

0.18

721

0.28

821

0.38

906

0.49

983

0.61

1125

 

620

0.21

741

0.31

840

0.42

925

0.54

1001

0.66

1200

 

643

0.23

762

0.35

 

 

0.46

944

0.58

1020

0.71

 

860

 

1275

 

666

0.27

784

0.38

880

0.50

964

0.63

1039

0.76

1350

 

690

0.30

805

0.42

900

0.55

983

0.68

1058

0.82

1425

 

714

0.34

827

0.47

921

0.60

1003

0.74

1077

0.88

1500

 

738

0.38

849

0.52

942

0.66

1024

0.80

1097

0.95

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AVAILABLE EXTERNAL STATIC PRESSURE (IN. WG)

 

 

 

CFM

 

 

1.2

 

1.4

 

1.6

1.8

 

 

2.0

 

RPM

BHP

RPM

BHP

RPM

 

BHP

RPM

BHP

RPM

BHP

 

 

 

 

 

 

 

Medium Static Option

 

 

 

 

High Static Option

 

900

 

1017

0.64

1082

0.76

1143

0.88

1200

1.01

1254

1.14

975

 

1035

0.68

1100

0.81

1160

 

0.93

1217

1.07

1271

1.20

1050

 

1053

0.73

1117

0.86

1177

0.99

1234

1.13

1288

1.27

1125

 

1071

0.78

1135

0.92

1195

1.05

1251

1.19

1305

1.34

1200

 

1089

0.84

1153

0.98

1212

1.12

1269

1.26

1322

1.41

1275

 

1107

0.90

1171

1.04

1230

1.19

1286

1.33

1340

1.49

1350

 

1126

0.96

1189

1.11

1249

1.26

1304

1.41

1357

1.57

1425

 

1145

1.03

1208

1.18

1267

1.33

1323

1.49

1375

1.66

1500

 

 

 

1227

1.25

1285

1.41

1341

1.58

1394

1.75

 

1164

1.10

NOTE: For more information, see General Fan Performance Notes on page 54.

 

 

 

 

Boldface indicates field--- supplied drive is required.

 

 

 

 

 

 

 

1. Recommend using field--- supplied fan pulley (part number KR11AG006) and belt (part number KR30AE039).

 

 

50TC**04

3 Phase

3 Ton Vertical Supply

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AVAILABLE EXTERNAL STATIC PRESSURE (IN. WG)

 

 

 

CFM

 

 

0.2

 

0.4

 

0.6

0.8

 

 

1.0

 

RPM

BHP

RPM

BHP

RPM

 

BHP

RPM

BHP

RPM

BHP

 

 

 

 

 

Field Supplied Drive1

 

Standard Static Option

Medium Static Option

900

 

566

0.14

690

0.23

791

0.32

879

0.42

957

0.52

975

 

590

0.17

711

0.26

811

0.36

897

0.46

975

0.57

1050

 

615

0.19

733

0.29

831

0.39

916

0.50

993

0.62

1125

 

640

0.22

755

0.33

851

0.43

936

0.55

1012

0.67

1200

 

666

0.25

778

0.36

 

 

0.48

956

0.60

1031

0.72

 

873

 

1275

 

692

0.29

802

0.41

894

0.53

976

0.65

1051

0.78

1350

 

719

0.33

825

0.45

916

0.58

997

0.71

1071

0.84

1425

 

746

0.37

850

0.50

939

0.63

1019

0.77

1091

0.91

1500

 

774

0.42

 

 

962

0.69

1041

0.83

1112

0.98

 

875

0.55

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AVAILABLE EXTERNAL STATIC PRESSURE (IN. WG)

 

 

 

CFM

 

 

1.2

 

1.4

 

1.6

1.8

 

 

2.0

 

RPM

BHP

RPM

BHP

RPM

 

BHP

RPM

BHP

RPM

BHP

 

 

 

 

 

 

 

Medium Static Option

 

 

 

 

High Static Option

 

900

 

1029

0.63

1095

0.75

1157

0.86

1216

0.99

1272

1.11

975

 

1046

0.68

1112

0.80

1174

 

0.92

1232

1.05

1287

1.18

1050

 

1064

0.73

1129

0.86

1190

0.98

1248

1.11

1304

1.25

1125

 

1082

0.79

1147

0.92

1208

1.05

1265

1.18

1320

1.32

1200

 

1100

0.85

 

 

1225

1.12

1282

1.26

1337

1.40

 

1165

0.98

1275

 

1119

0.91

1183

1.05

1243

1.19

1300

1.34

1354

1.49

1350

 

1139

0.98

1202

1.12

1262

1.27

1318

1.42

1372

1.57

1425

 

 

 

1221

1.20

1280

1.35

1336

1.51

1390

1.66

 

1159

1.05

1500

 

1179

1.13

1241

1.28

1300

1.44

1355

1.60

1408

1.76

NOTE: For more information, see General Fan Performance Notes on page 54. Boldface indicates field--- supplied drive is required.