50TC
APPENDIX I. MODEL NUMBER SIGNIFICANCE
Model Number Nomenclature
1 | 2 |
| 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 14 | 15 | 16 | 17 | 18 |
| |||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
| 5 | 0 | T | C | A | 0 | 6 | A | 0 | A | 5 | A | 0 | A | 0 | A | 0 | |||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ____ |
| ____ |
|
|
|
| ____ |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
Unit Heat Type |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Brand / Packaging | ||
50 = Elec heat pkg rooftop |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 0 = Standard | ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 1 = LTL | |
Tier / Model |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
TC = Entry tier (with Puron) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Electrical Options | |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
Heat Size |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| A = None | |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| C = | |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| D = Thru the base | |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| F = | |||
Refrig. System Options |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Service Options | |||||||
A = Standard refrigeration system |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||
D = 2 comp. upgrade |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 0 = None | ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 1 = Unpowered convenience outlet | |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 2 = Powered convenience outlet | |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||
Cooling Tons |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Intake / Exhaust Options | ||||||||
04 = 3 Ton |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| A = None |
|
|
| |||||
05 = 4 Ton |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| B = Temp econo w/ baro relief | ||||||||
06 = 5 Ton |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| F = Enthalpy econo w/ baro relief | ||||||||
07 = 6 Ton |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| K = 2 pos damper w/ baro relief | ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Base Unit Controls | |||||||||
Sensor Options |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 0 = Electromechanical | ||||||||||
A = None |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 1 = PremierLink DDC controller | ||||||||||
B = RA smoke detector |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 2 = Open protocol DDC controller | ||||||||||
C = SA smoke detector |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Design Rev |
|
|
|
|
| ||||||||
D = RA & SA smoke detector |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||
E = CO2 sensor |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Factory assigned |
|
|
| |||||||||
F = RA smoke detector & CO2 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Voltage |
|
|
|
|
|
|
|
|
| |||||
G = SA smoke detector & CO2 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||
H = RA & SA smoke detector & CO2 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 1 = 575/3/60 |
|
|
|
|
|
|
| |||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 3 = |
|
|
|
|
| ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 5 = |
|
|
|
|
| ||||||||
Indoor Fan Options |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 6 = 460/3/60 |
|
|
|
|
|
|
| |||||||
1 = Standard static option |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Coil Options (Outdoor Coil | |||||||||||||||||
2 = Medium static option |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||||||||||
3 = High static option |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| A = Al/Cu |
|
|
|
|
|
|
| |||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| B = Precoat Al/Cu |
|
|
| ||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| C = E coat Al/Cu |
|
|
| ||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| D = E coat Al/Cu | |||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| E = Cu/Cu |
|
|
|
|
|
|
| ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| F = Cu/Cu |
|
|
|
|
| ||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Serial Number Format
POSITION NUMBER |
| 1 |
| 2 | 3 | 4 |
| 5 |
| 6 |
| 7 |
| 8 | 9 | 10 |
TYPICAL |
| 1 |
| 2 | 0 | 8 |
| G |
| 1 |
| 2 |
| 3 | 4 | 6 |
| POSITION |
|
|
|
|
| DESIGNATES |
|
|
|
|
| ||||
|
|
|
|
| Week of manufacture (fiscal calendar |
|
|
| ||||||||
|
|
|
|
| Year of manufacture (“08” = 2008) |
|
|
| ||||||||
| 5 |
|
|
| Manufacturing location (G = ETP, Texas, USA) |
|
| |||||||||
|
|
|
|
|
| Sequential number |
|
|
|
|
|
52