CAPACITOR Ð To remove the capacitor, perform the following steps:
1.Turn off unit power as described in GENERAL DISASSEMBLY section.
2.Open the control box (Figure 61) as detailed in the GENERAL DISASSEMBLY section of this manual.
3.Properly discharge the capacitor as described in the Capacitor section under Component Operation and Troubleshooting.
4.Remove the leads to the capacitor. Note the wire loca- tions to ease
5.Close the control box door and remove the screw hold- ing the capacitor.
6.Open the control box door and remove capacitor.
7.Reverse Steps 1 - 6 to reinstall.
FIGURE 61 Ð COMPONENT LOCATIONS
IN OPEN CONTROL BOX
FAN CYCLE SWITCH Ð The fan cycle switch is lo- cated on the right side of the control box. To remove the fan cycle switch, perform the following steps:
1.Turn off unit power as described in GENERAL DISASSEMBLY section.
2.Open the control box as described in GENERAL DISASSEMBLY section of this manual.
3.Remove the 3 wires from the fan cycle switch. See Figure 61 for location.
4.Push the snaps of the switch housing toward the switch with a pair of pliers or small screwdriver. Gently push the switch out of the housing.
5.Reverse Steps 1 - 4 to reinstall.
SELECTOR SWITCH Ð To remove the selector switch from the unit, perform the following steps:
1.Turn off unit power as described in GENERAL DISASSEMBLY section.
2.Remove thermostat knob and unit escutcheon. See Figure 58.
3.Open control box as described in the GENERAL DISASSEMBLY section of this manual.
4.Remove all the wires to the selector switch. Label wires to simplify
5.Remove the 2 screws mounting the switch and re- move switch. See Figure 61.
6.Reverse Steps 1 - 5 to reinstall.
31