Manuals
/
Carrier
/
Household Appliance
/
Air Conditioner
Carrier
manual
52S Series
Models:
52S
1
44
56
56
Download
56 pages
47.31 Kb
41
42
43
44
45
46
47
48
Troubleshooting
Install
Field Temperature Charts
General Disassembly
NON-USER Adjustable Switches
General Cleaning
Compressor Replacement
Disconnect ALL Power to Unit
Page 44
Image 44
44
52S SERIES
FIGURE 76 Ð 52S 12,000 BTU UNIT FIELD TEMPERATURE CHART Ð HIGH COOL Ð 50% RH
Page 43
Page 45
Page 44
Image 44
Page 43
Page 45
Contents
Service Technician Guide
Contents
Introduction
Summary of DANGERS, WARNINGS, and Cautions
Model Number Nomenclature
General Disassembly
To Disconnect Power for CORD- Connected Unit
To Open the Control BOX
To Remove the Unit from the Wall Sleeve
Duct Extension Screws
To Access INDOOR-AIR Section Components
Removing the AIR Baffle
To Remove the AIR Discharge Grille
To Remove the TOP Cover Ð Remove the screw
To Remove the Gusset
To Access OUTDOOR-AIR Section Components
To Remove the Discharge Deck
Removing Stator
General Cleaning
Cleaning and Safety
Component Cleaning Schedule
Consider the following safety issues before beginning
Monthly Cleaning
Cleaning the Indoor AIR Filter Ð Remove
Replacing the Indoor AIR Filter Ð Access
Tools Needed
Chassis
Cleaning the Vent AIR Filter
Replacing the Vent AIR Filter
Disconnect ALL Power to Unit
Seasonal Cleaning
Accessing the Indoor and Outdoor
Cleaning the Indoor and Outdoor Coils
Accessing the Indoor FAN and Indoor
Coils section
Section Components on
Cleaning the Heater Assembly Ð Once
Cleaning the Indoor FAN and FAN
Disconnect ALL Power to the Unit
Compressor
Rotary Compressor Components
Compressor Troubleshooting
Basic Hermetic Compressor Electrical Measurements
Basic Compressor Troubleshooting Guide
Compressor Replacement
SHORTED/OPEN Windings Test
Disconnect all power to unit
Removing the Compressor Ð Follow the steps
Installed Filter Drier
Refrigerant Charging Ð Every mechanical
Heater Removal
Heaters
Common Causes Heater Failure
Removing Heater Screws
Operating Controls
Typical 52S Unit Operating Controls
Description of Switch Settings
NON-USER Adjustable Switches
High Heat or High Cool Ð Push button
Outside or Vent AIR Ð Push the FAN only
Sequence of Operation
HEAT/COOL Units Figure
Cooling only Units Figure
Heat Pump Units Figure
Indoor Thermostat Heat Pump Units
Component Operation and Troubleshooting
Tools Needed
Indoor Thermostat IT CONTACTS, ALL 52SQ AA and CP Models
Outdoor Frost Thermostat Heat Pump Units
Locked OUT
Capacitor Test
Electrical Components Removal and Replacement
Outdoor Frost Thermostat Screws
Component Locations Open Control BOX
Basic FAN Motor Electrical Tests
FAN Motor Troubleshooting
FAN Motor
FAN Motor Troubleshooting Chart Typical 208/230 Volt Motors
Typical 265 Volt Motors
FAN Motor Replacement
Removal
Field Temperature Charts
52S Series
Page
52S Series
Page
52S Series
Page
52S Series
Page
52S Series
Page
52S Series
Page
52S Series
Page
52S Series
Wiring Schematics
Wiring Schematic 52SC Ð 208/230 V and 265 V AA and CP Units
Wiring Schematic 52SE Ð 208/230 V and 265 V AA and CP Units
Wiring Schematic 52SE Ð 208/230 V and 265 V RC Units
Wiring Schematic 52SQ Ð 208/230 V and 265 V AA and CP Units
Wiring Schematic 52SQ Ð 208/230 V and 265 V RC Units
Most Frequent Ptac Service Questions
Top
Page
Image
Contents