52S

SERIES

CAP

Ð Capacitor

COMP

Ð Compressor

FCS

Ð Fan Cycle Switch

FM

Ð Fan Motor

HTR

Ð Heater

IT

Ð Indoor Thermostat

LÐ Power Supply Line

OL

Ð Overload

PL

Ð Plug

PLS

Ð

Primary Limit Switch

SLS

Ð

Secondary Limit Switch

LEGEND

ST Ð Start Thermistor

SW Ð Selector Switch

Component Connection (Marked)

Component Connection (Unmarked)

Accessory or Optional Wiring Factory Wiring

To Indicate Common Potential Only. Not to Represent Wire

SWITCH

CONTACTS MADE

POSITION

 

OFF

FCS TO LS

FAN

L1 TO LO*, FCS1 TO LS

LO HEAT

FCS2 TO LO, IT1 TO LS,

L2 TO HTR, FCS1 TO LS

 

HI HEAT

FCS2 TO HI, IT1 TO LS,

L2 TO HTR, FCS1 TO LS

 

LO COOL

FCS2 TO LO, COMP TO FCS1,

COMP TO IT3

 

NOTES:

1.Recommended for use on grounded power supply only.

2.Compressor and fan motor thermally protected.

3.Use copper conductors only.

4.All wiring must conform with NEC (National Electrical Code) and local codes.

5.Dashed lines indicate components when used.

HI COOL

FCS2 TO HI, COMP TO FCS1,

COMP TO IT3

 

*L1 to MED, some models.

FIGURE 84 Ð WIRING SCHEMATIC; 52SE Ð 208/230 V AND 265 V AA AND CP UNITS

52

Page 52
Image 52
Carrier manual Wiring Schematic 52SE Ð 208/230 V and 265 V AA and CP Units