Power Management

The Supervisor module checks the PSU status every three seconds by comparing the current state to the previously saved PSU state.

Figure 4.2 Power Management Priority

1

2

3

4

5

6

The Power Management Process

The power management process is activated in the SPV only if there is a change in power requirements or supply caused by one of the following events:

Power-up sequence

PSU removal if there are two PSUs

PSU insertion if there is only one PSU

I/O module insertion

I/O module removal

Administratively enabling/disabling a slot

Removing both supervisors turns off the entire system.

In case of power failure in a module, the Supervisor module receives an indication from the failed module. The Supervisor module will turn off the I/O module and issues a warning.