Turbomachinery Package Specification | Titan 250 Generator Set |
|
|
Construction Materials
Piping, Manifolds, and Tubing < 10.2 cm (4 in.) | 316L Stainless Steel (Unless Otherwise Specified) | |
Note (a) |
|
|
Piping, Manifolds, and Tubing > 10.2 cm (4 in.) | Carbon Steel (Unless Otherwise Specified) | |
Note (a) |
|
|
Piping Interface Connections | 316L Stainless Steel (Unless Otherwise Specified) | |
Flange Assembly Hardware | 316L Stainless Steel | |
Pipe Support Brackets | Carbon Steel (Standard) | |
|
| 316L Stainless Steel (Optional) |
Pipe Flexible Couplings | Carbon Steel (Standard) | |
|
| 316L Stainless Steel (Optional) |
Tubing Dual Ferrule Compression Fittings | 316L Stainless Steel | |
Sliding Lube Oil Drain Couplings and Plates | Carbon Steel (Standard) | |
|
| 316L Stainless Steel (Optional) |
Lube Oil Vent Flame Arrestor | Aluminum | |
Electrical System Certifications |
| |
NEC |
| Class 1, Group D, Division 1 or 2 |
CENELEC |
| Zone 1 or 2, Group II |
CE, ATEX |
| Zone 2, Group II |
| ||
Optional Motor Voltage Ratings | 380, 400, or 415 VAC, 50 Hz | |
|
| 460 VAC 60 Hz |
| ||
Optional Battery Charger Voltage Ratings | 220, 230, 240, 380, 400, 415, 440, 460, or 480 | |
|
| VAC, 50 Hz or 60 Hz |
| ||
Optional Package Lighting and Space Heater | 120, 220, 230, or 240 VAC, 50 Hz or 60 Hz | |
Voltage Ratings |
|
|
|
|
|
Ingress Protection (IP) Ratings |
| |
Onskid Junction Boxes | IP56 to IP66 | |
Control Console |
| IP50 |
Battery Charger, NEC | IP22 | |
Battery Charger, CE | IP31 | |
Solar’s Applicable Engineering Specifications |
| |
ES | Fusion Welding |
|
ES | Standard Paint Program – Turbomachinery | |
ES 1593 | Guidelines for NEC Compliance of Solar’s Product Lines: Class I, Group D, Division 1 | |
| and Division 2 |
|
ES 1762 | Standards and Practices for Electrical Systems for Gas Turbine Packages Installed In | |
| Hazardous Areas (CENELEC/IEC Standards – European ATEX Directive 94/9/EC) | |
ES 2201 | Auxiliary Air |
|
ES 2231 | Standards and Practices for The Design and Installation of Cable Channels and TC | |
| Rated Cables Installed In Class 1, Division 2 Hazardous Areas | |
Solar’s Applicable Product Information Letters |
| |
PIL 127 | Product Certification |
|
Notes: |
|
|
(a)All package piping is fabricated from 316L stainless steel with the exception of lube oil vent lines and any piping welded directly to a carbon steel lube oil tank or tank cover.
© 2008 Solar Turbines Incorporated. All rights reserved. | TPS250GS/908 - Preliminary |
9