Turbomachinery Package Specification | Titan 250 Generator Set |
|
|
During initial turbine generator acceleration, the excitation power is switched off. At approximately 80% speed, the PMG output is connected to the excitation power contacts and voltage begins to build. The CGCM then provides controlled exciter field current at a level to maintain the generator terminal voltage at a predetermined value established by the operator. A potential transformer (usually supplied with the switchgear) provides a voltage level signal to the CGCM. By sensing the generator output voltage and controlling the power to the brushless exciter, the CGCM automatically maintains the generator output voltage at a constant level at all load conditions.
Since the PMG output power is independent of the main generator line voltage and current levels, there is no need for additional auxiliary equipment to provide power to the CGCM during transient conditions. The PMG provides sufficient generator terminal voltage during conditions of high generator line current to allow for selective tripping during a
In addition to voltage regulation, the following generator control modes are also available:
•Speed/Load Control
−Isochronous (Isoch) Speed Control
−Droop Speed Control
−Kilowatt Import Control
•Reactive Compensation
−Droop Voltage Control
•Power Factor Control
•Reactive Load Volt Amp Reactive Control
−Differential Cross Current Control
10.2.3Breaker SynchronizationThe control system provides automatic generator breaker synchronization control when paralleling to the bus. Automatic synchronization can be initiated by the operator or by a remote signal received from a supervisory control system. If manual synchronization is required, an optional generator metering panel must be included. Synchronization control is provided by the CGCM.
10.2.4Auto Start and Synchronizing SystemWhen the generator set is in standby mode, the control system will automatically start the generator set, accelerate the engine to loading speed, and synchronize the generator breaker to the bus upon receipt of a supervisory command. If the control system detects a hot bus, it will synchronize the generator to the bus and close the breaker. If the control system detects a dead bus, it will close the generator breaker without synchronization.
10.2.5Kilowatt Import ControlThe kW import control system controls the real load (kW) when the generator set is in parallel with a large power source. When kW import control is enabled, the control system monitors the load imported from the utility and adjusts the turbine generator set fuel flow to maintain a preset amount of imported power. When it is not desirable to export power to the utility, kW import control is normally selected. While in parallel with a