Troubleshooting

Warnings

Warning events let you know that something related to the controller or an array has a problem. You should correct the problem as soon as possible. Table 9-1below defines each warning event and recommends the action you should take.

Table 9-1. Warning events

Event

Definition

Recommended Action

BATT FAIL INFO A warning condition in the battery pack and/or charging interface has been detected.

Replace the battery. Refer to the enclosure’s documentation.

REPLACE

The battery is approaching its

Replace the battery.

BATTERY

3-year life span.

 

 

 

 

ARRAY

One or more drives were

Add a spare to the array or to the

CRITICAL

downed and the array is online

spare pool. Then replace the bad

 

but no longer fault tolerant.

drives. See Adding a Dedicated

 

 

Spare on page 6-2or Adding a

 

 

Spare to the Spare Pool on

 

 

page 6-5.

DRIVE DOWN

An error occurred with the

 

drive and it was downed,

 

removing it from the active

 

array.

Add a spare to the array or to the spare pool. Then replace the bad drive. See Adding a Dedicated Spare on page 6-2or Adding a Spare to the Spare Pool on page 6-5.

SPARE

The drive still contains

Clear the metadata from the spare

UNUSABLE

metadata that must be cleared.

drive. See Clearing Metadata

 

 

from a Drive on page 8-4.

SMART EVENT

A disk drive IEPC

 

(informational exceptions page

 

control) predictive failure

 

message was received. No

 

actions by the controller are

 

taken on the drive for these

 

events.

Run diagnostics available from your operating system on the affected drive. Replace the drive, if necessary.

9-7

Page 131
Image 131