Troubleshooting
Warnings
Warning events let you know that something related to the controller or an array has a problem. You should correct the problem as soon as possible. Table
Table
Event | Definition | Recommended Action |
BATT FAIL INFO A warning condition in the battery pack and/or charging interface has been detected.
Replace the battery. Refer to the enclosure’s documentation.
REPLACE | The battery is approaching its | Replace the battery. |
BATTERY |
| |
|
|
|
ARRAY | One or more drives were | Add a spare to the array or to the |
CRITICAL | downed and the array is online | spare pool. Then replace the bad |
| but no longer fault tolerant. | drives. See Adding a Dedicated |
|
| Spare on page |
|
| Spare to the Spare Pool on |
|
| page |
DRIVE DOWN | An error occurred with the |
| drive and it was downed, |
| removing it from the active |
| array. |
Add a spare to the array or to the spare pool. Then replace the bad drive. See Adding a Dedicated Spare on page
SPARE | The drive still contains | Clear the metadata from the spare |
UNUSABLE | metadata that must be cleared. | drive. See Clearing Metadata |
|
| from a Drive on page |
SMART EVENT | A disk drive IEPC |
| (informational exceptions page |
| control) predictive failure |
| message was received. No |
| actions by the controller are |
| taken on the drive for these |
| events. |
Run diagnostics available from your operating system on the affected drive. Replace the drive, if necessary.