Chaparral G5312/G7313, K5312/K7313 manual Hardware Installation, Connecting the Controller

Models: K5312/K7313 G5312/G7313

1 160
Download 160 pages 20.09 Kb
Page 25
Image 25

2

Hardware Installation

This chapter explains how to connect the controller in your RAID enclosure to your network and host computer.

Connecting the Controller

Your controller is already installed in an enclosure. Before you configure the controller and create arrays, you must connect the controller, which has two types of data connections:

SCSI channel (G5312 and K5312)—permitting connection to a server (host).

Fibre Channel (G7313 and K7313)—permitting connection to other FC devices, typically through an arbitrated loop or SAN with fabric.

RS-232 serial port—for configuration and management of the controller.

Connecting to the SCSI Port

You can connect the controller (G5312 and K5312) to a SCSI port. Refer to your enclosure documentation for the type of connector required.

To connect to the SCSI port:

1Be sure the enclosure is turned off.

2Connect one end of the SCSI cable to the SCSI port on the enclosure.

3Connect the other end of the SCSI cable to a server’s SCSI port.

Connecting to the Fibre Channel Port

You can connect the controller (G7313 and K7313) to an FC HBA or to an FC switch or hub. You must use proper FC components. Refer to your enclosure documentation for the type of connector required.