To enable dynamic spares:

1From the System Menu, select Configuration Menu and press Enter. The Configuration Menu screen displays.

2Select Option Configuration and press Enter. The Option Configuration screen displays.

3Select Dynamic Spare Configuration and press Enter.

The Dynamic Spare Config screen displays. The current setting is marked with an * next to it.

4Select Enabled and press Enter. The Rescan Rate screen displays.

5Enter the rescan rate in minutes.

This tells the controller how often it should look for an available drive by rescanning the bus. Remember that rescanning the bus frequently can affect performance. If you have a SEP, the dynamic spare configuration will not rescan the bus. The SEP will detect the new drive and tell the controller to rescan and the rescan rate you set here will not affect the system.

The system confirms the change.

6Select Yes and press Enter.