Chaparral G5312/G7313, K5312/K7313 manual Managing the Spare Pool, Adding a Spare to the Spare Pool

Models: K5312/K7313 G5312/G7313

1 160
Download 160 pages 20.09 Kb
Page 77
Image 77

Managing Spares

Managing the Spare Pool

The spare pool lets you have one or more disk drives available for the reconstruction of redundant arrays (Mirrored [RAID 1 and RAID 10] and Parity [RAID 3, RAID 4, RAID 5, and RAID 50]) arrays. Once you assign a drive to the spare pool, it is not available for use as an array member or as a dedicated spare.

If a pool spare is too small (smaller than an individual member in an array), the controller cannot use it.

Adding a Spare to the Spare Pool

You can add up to eight drives to the spare pool to reconstruct any critical array on the controller. After an array has started using a pool spare, other critical arrays are prevented from using it. For a pool spare to be used, it must be at least as large as the minimum drive size in the array.

To add a pool spare:

1From the System Menu, select Pool Spare Menu and press Enter. The Pool Spare Menu screen displays.

6-5

Page 77
Image 77
Chaparral G5312/G7313, K5312/K7313 manual Managing the Spare Pool, Adding a Spare to the Spare Pool, To add a pool spare