Chaparral K5312/K7313, G5312/G7313 manual Errors, Warn

Models: K5312/K7313 G5312/G7313

1 160
Download 160 pages 20.09 Kb
Page 132
Image 132

G- and K-Series User’s Guide

Table 9-1. Warning events (Continued)

Event

Definition

Recommended Action

ARRAY OFFLINE More than one drive in a RAID 0 or volume set went down bringing the array to an offline state. This array is no longer accessible by the host.

Replace the bad drive and restore the data from backup.

VOLT/TEMP

The analog to digital convertor

WARN

monitored a temperature and/or

 

voltage in the warning range.

Check that the controller’s fan is running. Check that the ambient temperature is not too warm. See Specifications on page 1-7.

UNWRITABLE

The SDRAM cache has battery

Either determine which drives are

CACHE

backed up data, and the arrays

missing and reinstall them, or

 

assigned to this data are not

select Yes when asked if you want

 

present.

to discard this data.

 

 

 

SDRAM CORR

A correctable single bit

If this error occurs frequently,

ECC

SDRAM ECC error.

replace the memory.

 

 

 

Errors

Error events let you know that something related the enclosure, controller, or disk drives has failed and requires immediate attention. Table 9-2defines each error event and recommends the action you should take.

Table 9-2. Error events

Event

Definition

Recommended Action

VOLT/TEMP

The analog to digital

Check that the controller’s fan is

FAIL

convertor monitored a

running. Check that the ambient

 

temperature and/or voltage in the

temperature is not too warm. See

 

failure range.

Specifications on page 1-7.

ENCLOSURE

Enclosure-specific general

Check the status of the enclosure.

FAIL

purpose IO trigger a failure

Refer to the enclosure’s

 

condition.

documentation.

 

 

 

BATTERY

A failure in the battery pack

Replace the controller’s battery.

FAILED

and/or charging interface has

 

 

been detected.

 

 

 

 

9-8

Page 132
Image 132
Chaparral K5312/K7313, G5312/G7313 manual Errors, Warn