Filter counter

Setting

Filter counter

This function is used to set a frequency for the filter replacement.

Use the Point ▲▼ buttons to select Filter counter and then press the Point or the SELECT button to access the submenu items.

Filter counter

Show the total accumulated time of the filter

 

use timer setting.

Timer

To set a timer, when the projector reaches

 

the time, the Filter replacement icon (Fig. 1)

 

appears on the screen and the total

 

accumulated time turns red, indicating that

 

the filter replacement is necessary. If the

 

filter is out of scroll and the projector reaches

 

a time set in the timer setting, Fig. 2 appears

 

on the screen, indicating that the filter

 

cartridge replacement is necessary.

Filter counter reset..When replacing the Filter cartridge, reset the Filter counter and the Scroll remaining (p.65).

Scrolls remaining . When the filter scroll is counted down to 1, Scroll remaining on the screen is showing 0 scroll(s) , the last scroll icon (Fig. 3) appears on the screen. When the filter scroll is counted down to 0, the Filter cartridge replacement icon (Fig. 4) appears on

the screen and the WARNING FILTER indicator lights orange, indicating that the filter cartridge replacement is necessary.

Scroll counter Reset..When replacing the Filter cartridge, reset the Filter counter and the Scroll remaining (p.65).

￿Note:

Do not reset the counter when the filter or the filter cartridge is not replaced.

Timer setting notifies that the filter needs replacement. To replace the filter, use the filter control function (p.56).

Filter counter

Filter counter

150 H

 

 

 

 

 

Timer

 

 

400 H

Filter counter reset

 

 

 

Scrolls remaining

 

9 Scroll(s)

Scroll counter Reset

 

 

 

 

 

 

 

 

Press the SELECT button to select Timer and then use the Point ▲▼ buttons to set the timer. Select from (Off/ 400H/700H/1000H) depending on the use environment.

Fig.1 Filter replacement icon

Filter replacement icon appears on the screen at a set time.

Fig.2

Fig.3 Last scroll icon

Last scroll icon appears on the screen when the filter is down to the last scroll.

Fig.4 Filter cartridge replacement icon

Filter cartridge replacement icon appears on the screen when the filter scroll is counted down to 0 scroll.

Test pattern

Various test pattern are available for use when setting up the projector.

Factory default

This function returns all setting values except for User logo, PIN code lock, Logo PIN code lock, Lamp counter, and Filter counter to the factory default settings.

￿Note:

Fig.1, Fig. 2, Fig. 3 and Fig. 4 appear at turning on and selecting input source.

Fig.1, Fig. 2, Fig. 3 and Fig. 4 will not appear when the Display function is set to Off (p.52) or during “Freeze” (p.30).