Table 1-1

LED Functions (continued)

 

 

 

 

 

LED

Color or State

Description

 

 

 

 

 

FAN

Off

No power to the switch or fans (the tray may

 

 

 

not be plugged in especially if one or more of

 

 

 

the power supplies status LED is green)

 

 

Green

Fan tray operational

 

 

Red

Fault detected

 

 

 

 

 

PS1 and

Off

No power to the PS

 

PS2

Green

Operational1

 

 

Red

Fault detected or the on/off switch is set to

 

 

 

off while the power supply is plugged in

 

 

 

 

 

1.If either LED is green and the other is OFF the power supply is probably not plugged in. If it is red, the supply is either plugged in and not switched on or it is faulty. It may be necessary to use the CLI for further status information.

Chassis Cooling

Note For environmental specifications, see Chapter 2, “Site Planning.”

The hot-swappable system fan tray provides cooling air for the internal chassis components. The fans exhaust air to the rear, and fresh air is drawn in from the sides of the chassis.

Caution When the fan tray is removed, internal circuitry is exposed that should not be touched by tools or fingers. The system should not be left operating without a fan tray for longer than is necessary to replace a faulty fan tray with a new one.