Chapter 3 Installing the Switch

Connecting DC Power to the Switch

Step 1 Prior to connecting the power supply to a power source, ensure that all of the site power and grounding requirements described in Chapter 2, “Site Planning,” have been met and the chassis is properly grounded as described in the “Grounding Requirements” section on page 2-6.

Step 2 Remove the safety cover from the power terminal.

Step 3 Connect the power supply ground terminal to earth ground.

Figure 3-6 DC Power Supply

DC input terminals

Handle

Status LEDs

120697

Step 4 Connect the positive and negative power cables into the power supplies using a number 2 Phillips screwdriver.

Note The DC power cables may use AWG #10 to AWG #12 wire.

 

Catalyst 4900 Series Switch Installation Guide

3-12

78-18039-02

Page 58
Image 58
Cisco Systems 4900 Series manual DC Power Supply