Table2-3 DC Power Requirements and Heat Dissipation
Module Number/Module Type
DC-Input
Power
(Watts)
Heat Diss.
(BTU/HR)
Input Current
48V DC
(Amps)
60V DC
(Amps)
Cisco 7609 Internet Router chassis
(with fans)
167 569 3.47 2.78
WS-X6K-S2U-MSFC2 173 590 3.6 2.88
OSM-2OC12-POS-MM, -SI, -SL
OC-12 POS, 2-port
190 648 3.95 3.16
OSM-4OC12-POS-MM, -SI, -SL
OC-12 POS, 4-port
270 921 5.62 4.50
OSM-4OC12-POS-SI+
OC-12 POS, 4-port
257 877 5.35 4.28
OSM-4OC3-POS-SI
OC-3 POS, 4-port
138 4.70 2.87 2.30
OSM-8OC3-POS-MM, -SI, -SL
OC-3 POS, 8-port
202 688 4.20 3.36
OSM-16OC3-POS-MM, -SI, -SL
OC-3 POS, 16-port
287 981 5.99 4.79
OSM-16OC3-POS-SI+
OC-3 POS, 16-port
271 925 5.65 4.52
OSM-2OC12-ATM-MM, -SI
OC-12 ATM, 2-port
204 698 4.26 3.41
OSM-2OC12-ATM-MM+, -SI+
OC-12 ATM, 2-port
226 771 4.70 3.76
OSM-1OC48-POS-SS, -SI, -SL
OC-48 POS, 1-port
240 819 5.00 4.00