Chapter 3 Power Supply Installation

Power-Supply Module Installation

Figure 3-11 Stripping the Input Power Source Wire

0.25 in. (6.3 mm) ± 0.02 in. (0.5 mm)

60531

Step 5 Insert the wire into a spade terminal, and crimp it to the wire. You can also use a ring or flanged spade terminal as listed in the “Equipment That You Need” section on page 3-4.

Figure 3-12 Crimping the Spade Terminal Lug

207427

Step 6 Loosen the terminal screw, and slide the terminal under the screw and washer. See Figure 3-14.

Note Use the appropriate terminal screws, depending on whether you are installing a high-voltage (AC or DC) or a low-voltage (DC) power supply.

Step 7 To connect the AC power:

a.Connect the line wire into the terminal screw labeled L and the neutral wire into the terminal screw labeled N.

b.Make sure that you cannot see any wire lead. Only wire with insulation should extend from the terminal screw.

Cisco IE 3010 Switch Hardware Installation Guide

3-10

78-19581-02

 

 

Page 60
Image 60
Cisco Systems IE 3010 manual Stripping the Input Power Source Wire