Segment 2: On=0.38s, Off=0s, with Frequency 2
Segment 3: On=0.38s, Off=0s, with Frequency 3
Segment 4: On=0s, Off=4s, with no frequency components
Total Tone Length = 20s
• ProvisioningRuleSyntax – Scripting syntax used to define configuration resync and firmware
upgrade rules. Refer to the provisioning discussion in the next section for a detailed explanation
of the syntax.
• DialPlanScript – Scripting syntax used to specify line 1 and line 2 dial plans. Refer to the dial
plan section of this document for a detailed explanation of the syntax.
4.1.1. Conventions
• <Par Name> represents a configuration parameter name. In a profile, the corresponding
tag is formed by replacing the space with an underscore “_”, such as Par_Name.
• An empty default value field implies an empty string < “” >.
• The PHONE ADAPTER shall continue to use the last configured values for tags that are
not present in a given profile.
• Templates are compared in the order given. The first, not the closest, match is selected.
The parameter name must match exactly.
• If more than one definition for a parameter is given in a configuration file, the last such
definition in the file is the one that will take effect in the PHONE ADAPTER.
• A parameter specification with an empty parameter value forces the parameter back to its
default value. To specify an empty string instead, use the empty string “” as the parameter
value.
Provisioning is controlled by the following parameters (firmware upgrades are discussed later in this
section).
• Provision_Enable
• Resync_On_Reset
• Resync_Random_Delay
• Resync_Periodic
• Resync_Error_Retry_Delay
• Forced_Resync_Delay
• Resync_From_SIP
• Resync_After_Upgrade_Attempt
• Resync_Trigger_1
• Resync_Trigger_2
• Resync_Fails_On_FNF
• Profile_Rule
• Profile_Rule_B
• Profile_Rule_C
• Profile_Rule_D
• Log_Resync_Request_Msg
• Log_Resync_Success_Msg
• Log_Resync_Failure_Msg
© 2004 Linksys Proprietary (See Copyright Notice on Page 2)
35