Power Supply Status
This section describes the power supply LED indicators for the Cisco Nexus 3000 Series switches.
Table D-2 describes the status indi cated by the two LEDs on each power supply.
Port LEDs
Table D-3 lists the LED descriptions for the RJ-45 Ethernet port LEDs.
Port LED Indicates LED
status
Off
Solid on
(green)
Solid on
(amber)
Blinking
(amber)
Table D-1 LEDs for the Cisco Nexus 3000 Series Fabric Extenders (continued)
Component LED Status Description
Tab l e D-2 Power Supply Statu s Indicated by the OK and FAIL LE Ds
Condition OK LED Status (Green) FAIL LED Status (Amber)
No AC power to the power supplies Off Off
Power supply failure (includes
overvoltage, overcurren t,
overtemperature, and fan failure)
Off On
Power supply warning events where the
power supply continues to operate
(high temperature, high power, and
slow fan)
Off 1 blinking
AC present/voltage standby (VSB) on,
and power supply unit off
blinking Off
Power supply On and OK On Off
Tab l e D-3 Ethernet Port LED Descriptions
LED Status Description
Left Off No link
Solid green Physical link