Appendix A Notifications, Fault Management, and Probable Cause Mapping

 

 

 

 

Probable Cause Mapping

 

Table A-34

CTM GateWay/CORBA Mapping for the ONS 15600 SDH R1.4 (continued)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CTM Internal Index (Not

 

TMF Mapping

 

NE Native Probable Cause

Reported in the Notification)

 

 

 

 

 

 

 

 

 

UNIDENTIFIED

Far end of fiber is provisioned with different ring ID

50191

 

 

 

 

 

 

 

 

 

 

 

 

 

UNIDENTIFIED

BLSR multinode table update completed

50192

 

 

 

 

 

 

 

 

 

 

 

 

 

UNIDENTIFIED

MSSP multinode table update completed

50193

 

 

 

 

 

 

 

 

 

 

 

 

 

UNIDENTIFIED

BLSR out of sync

50194

 

 

 

 

 

 

 

 

 

 

 

 

 

UNIDENTIFIED

MSSP out of sync

50195

 

 

 

 

 

 

 

 

 

 

 

 

 

UNIDENTIFIED

Far-end lockout of protection—span

50196

 

 

 

 

 

 

 

 

 

 

 

 

 

UNIDENTIFIED

Admin logout of user

50198

 

 

 

 

 

 

 

 

 

 

 

 

 

UNIDENTIFIED

Admin lockout of user

50199

 

 

 

 

 

 

 

 

 

 

 

 

 

UNIDENTIFIED

Admin lockout clear

50200

 

 

 

 

 

 

 

 

 

 

 

 

 

UNIDENTIFIED

Automatic logout of idle user

50201

 

 

 

 

 

 

 

 

 

 

 

 

 

UNIDENTIFIED

Login of user

50202

 

 

 

 

 

 

 

 

 

 

 

 

 

SECURITY_VIOLATION

Invalid login—locked out

50203

 

 

 

 

 

 

 

 

 

 

 

 

 

SECURITY_VIOLATION

Invalid login—already logged on

50204

 

 

 

 

 

 

 

 

 

 

 

 

 

SECURITY_VIOLATION

Invalid login—password

50205

 

 

 

 

 

 

 

 

 

 

 

 

 

SECURITY_VIOLATION

Invalid login—username

50206

 

 

 

 

 

 

 

 

 

 

 

 

 

UNIDENTIFIED

Logout of user

50207

 

 

 

 

 

 

 

 

 

 

 

 

 

UNIDENTIFIED

User locked out

50208

 

 

 

 

 

 

 

 

 

 

 

 

 

UNIDENTIFIED

Audit log 80 percent full

50209

 

 

 

 

 

 

 

 

 

 

 

 

 

UNIDENTIFIED

Audit log 100 percent full

50210

 

 

 

 

 

 

 

 

 

 

 

 

 

UNIDENTIFIED

TSC switched to alternate Ethernet port

50211

 

 

 

 

 

 

 

 

 

 

 

 

 

UNIDENTIFIED

Open I/O slot(s)

50212

 

 

 

 

 

 

 

 

 

 

 

 

 

UNIDENTIFIED

Software download failed

50213

 

 

 

 

 

 

 

 

 

 

 

 

 

UNIDENTIFIED

SNTP host failure

50214

 

 

 

 

 

 

 

 

 

 

 

 

 

UNIDENTIFIED

Equipment boot in progress

50215

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BER_SD

 

Signal degrade

50216

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BER_SF

 

Signal failure

50217

 

 

 

 

 

 

 

 

 

 

 

 

 

UNIDENTIFIED

Incorrect BPV density

50218

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TIM

 

TIM—section—trace identifier mismatch

50219

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TIM

 

TIM—regeneration section—trace identifier mismatch

50220

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AIS

 

AIS—multiplex section—alarm indication signal

50221

 

 

 

 

 

 

 

 

 

 

 

 

 

UNIDENTIFIED

RDI—multiplex section—remote defect indication

50222

 

 

 

 

 

 

 

 

 

 

 

 

 

UNIDENTIFIED

Synchronization status message—primary reference clock

50223

 

 

 

 

 

 

 

traceable (G811)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

UNIDENTIFIED

Synchronization status message—sync supply unit (transfer

50224

 

 

 

 

 

 

 

node) (G812T)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cisco Transport Manager Release 8.5 GateWay/CORBA User Guide and Programmer Manual

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OL-14253-01

 

 

 

 

A-125

 

 

 

 

 

 

 

Page 125
Image 125
Cisco Systems OL-14253-01 appendix 125