Appendix A Notifications, Fault Management, and Probable Cause Mapping

 

 

 

 

Probable Cause Mapping

 

 

Table A-24

CTM GateWay/CORBA Mapping for the ONS 15310 CL, ONS 15454 SONET, and ONS 15454 SDH R6.0 and

 

 

 

R8.0; ONS 15327 R6.0 (continued)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CTM Internal Index (Not

 

 

TMF Mapping

 

NE Native Probable Cause

Reported in the Notification)

 

 

 

 

 

 

 

 

 

 

UNIDENTIFIED

Automatic power control terminated on manual request

25638

 

 

 

 

 

 

 

 

 

 

 

 

 

UNIDENTIFIED

Fibre channel distance extension credit starvation

25639

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PLM

 

GFP user payload mismatch

25640

 

 

 

 

 

 

 

 

 

 

 

 

 

UNIDENTIFIED

GFP fibre channel distance extension mismatch

25641

 

 

 

 

 

 

 

 

 

 

 

 

 

UNIDENTIFIED

GFP fibre channel distance extension buffer starvation

25642

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BER_SF

 

GFP client signal fail detected

25643

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LOF

 

GFP loss of frame delineation

25644

 

 

 

 

 

 

 

 

 

 

 

 

 

UNIDENTIFIED

GFP extension header mismatch

25645

 

 

 

 

 

 

 

 

 

 

 

 

 

UNIDENTIFIED

Signal loss on data interface

25646

 

 

 

 

 

 

 

 

 

 

 

 

 

UNIDENTIFIED

Encapsulation mismatch—path

25647

 

 

 

 

 

 

 

 

 

 

 

 

 

UNIDENTIFIED

Encapsulation mismatch—VT

25648

 

 

 

 

 

 

 

 

 

 

 

 

 

UNIDENTIFIED

Encapsulation mismatch high order—path

25649

 

 

 

 

 

 

 

 

 

 

 

 

 

UNIDENTIFIED

Encapsulation mismatch low order—path

25650

 

 

 

 

 

 

 

 

 

 

 

 

 

UNIDENTIFIED

Synchronization loss on data interface

25651

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AIS

 

ODUk-1—alarm indication signal

25652

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AIS

 

ODUk-2—alarm indication signal

25653

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AIS

 

ODUk-3—alarm indication signal

25654

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AIS

 

ODUk-4—alarm indication signal

25655

 

 

 

 

 

 

 

 

 

 

 

 

 

UNIDENTIFIED

LCAS control word CRC check failure

25656

 

 

 

 

 

 

 

 

 

 

 

 

 

UNIDENTIFIED

Duplicate serial number detected on a pluggable entity

25657

 

 

 

 

 

 

 

 

 

 

 

 

 

UNIDENTIFIED

LCAS VCG member Tx side in DNU state

25658

 

 

 

 

 

 

 

 

 

 

 

 

 

UNIDENTIFIED

LCAS VCG member Tx side in ADD state

25659

 

 

 

 

 

 

 

 

 

 

 

 

 

UNIDENTIFIED

LCAS VCG member Rx side in FAIL state

25660

 

 

 

 

 

 

 

 

 

 

 

 

 

UNIDENTIFIED

Optimized 1+1 APS primary facility

25661

 

 

 

 

 

 

 

 

 

 

 

 

 

UNIDENTIFIED

Optimized 1+1 APS primary section mismatch

25662

 

 

 

 

 

 

 

 

 

 

 

 

 

UNIDENTIFIED

Optimized 1+1 APS invalid primary section

25663

 

 

 

 

 

 

 

 

 

 

 

 

 

UNIDENTIFIED

Composite clock high line voltage

25664

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BER_SD

 

BER threshold exceeded for signal degrade—VT

25665

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BER_SF

 

BER threshold exceeded for signal failure—VT

25666

 

 

 

 

 

 

 

 

 

 

 

 

 

UNIDENTIFIED

Alarms suppressed on out-of-group VCAT member

25667

 

 

 

 

 

 

 

 

 

 

 

 

 

UNIDENTIFIED

Span length out of range

25668

 

 

 

 

 

 

 

 

 

 

 

 

 

UNIDENTIFIED

Temperature reading mismatch between SC cards

25669

 

 

 

 

 

 

 

 

 

 

 

 

 

UNIDENTIFIED

Voltage reading mismatch between SC cards

25670

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TIM

 

VT path trace identifier mismatch

25671

 

 

 

 

 

 

 

 

 

 

 

 

 

UNIDENTIFIED

BLSR software version mismatch

25672

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cisco Transport Manager Release 8.5 GateWay/CORBA User Guide and Programmer Manual

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OL-14253-01

 

 

 

 

A-83

 

 

 

 

 

 

 

Page 83
Image 83