A-65
Cisco Transport Manager Release 8.5 GateWay/CORBA User Guide and Programmer Manual
OL-14253-01
AppendixA Notifications, Fault Management, and Probable Cause Mapping
Probable Cause Mapping
A.5.8 CTM GateWay/CORBA Mapping—ONS 15310 CL, ONS 15454 SONET, and ONS 15454 SDH R6.0 and R8.0; ONS 15327 R6.0
The following table lists the CTM GateWay/CORBA mapping for the ONS 15310 CL, ONS 15454
SONET, and ONS 15454 SDH R6.0 and R8.0, and for the ONS 15327 R6.0.
TableA-24 CTM GateWay/CORBA Mapping for the ONS 15310 CL, ONS 15454 SONET, and ONS 15454 SDH R6.0 and
R8.0; ONS 15327 R6.0
TMF Mapping NE Native Probable Cause
CTM Internal Index (Not
Reported in the Notification)
UNIDENTIFIED Normal condition 25000
ENV Failure detected external to the NE 25001
ENV External error 25002
UNIDENTIFIED Excessive switching 25003
UNIDENTIFIED Incoming failure condition 25004
AIS Alarm indication signal 25005
AIS Alarm indication signal—line 25006
AIS Alarm indication signal—path 25007
FOP_APS APS channel failure 25008
FOP_APS Byte failure 25009
FOP_APS Protection switching channel match failure 25010
FOP_APS Automatic protection switch mode mismatch 25011
FOP_APS Far-end protection line failure 25012
UNIDENTIFIED Bipolar violation 25013
UNIDENTIFIED Carrier loss on the LAN 25014
UNIDENTIFIED STS concatenation error 25015
UNIDENTIFIED Excess collisions on the LAN 25016
UNIDENTIFIED Facility failure 25017
UNIDENTIFIED Far-end block error 25018
LOF Loss of frame 25019
LOP Loss of pointer 25020
LOP Loss of pointer—path 25021
LOS Loss of signal 25022
UNIDENTIFIED Out of frame 25023
UNIDENTIFIED Path selector failure 25024
RAI Remote alarm indication 25025
RAI Remote failure indication 25026
RAI Remote failure indication—line 25027
RAI Remote failure indication—path 25028
BER_SD Signal degrade 25029