Cisco Transport Manager Release 8.5 GateWay/CORBA User Guide and Programmer Manual
OL-14253-01
AppendixA Notifications, Fault Management, and Probable Cause Mapping
Probable Cause Mapping
EQPT Battery input 2 voltage level low BATINSTAT-2-BAT_LOW 749
EQPT Battery output 1 voltage level low BATOUTSTAT-1-BAT_LOW 750
EQPT Battery output 2 voltage level low BATOUTSTAT-2-BAT_LOW 751
TX_DEGRADE Transmit L band power level low TXLBPWR-1-LOW 752
UNIDENTIFIED Receive L band power level low RXLBPWR-1-LOW 753
UNIDENTIFIED Receive OSC optical power level low RXOSCPWR-1-LOW 754
TX_DEGRADE Transmit total optical power level low TXTOTPWR-1-LOW 755
UNIDENTIFIED Express channels input power 1 high T-INPPWREXP-1-HIGH 756
UNIDENTIFIED Express channels input power 1 degrade T-INPPWREXP-1-POWER_DEG 757
UNIDENTIFIED Express channels input power 1 fail T-INPPWREXP-1-POWER_FAIL 758
UNIDENTIFIED Add channels input power 1 high T-INPPWRADD-1-HIGH 759
UNIDENTIFIED Add channels input power 1 degrade T-INPPWRADD-1-POWER_DEG 760
UNIDENTIFIED Add channels input power 1 fail T-INPPWRADD-1-POWER_FAIL 761
EQPT DPRAM failure DPR_FAIL-1-DPR_CONNECT_OFF 762
EQPT Internal configuration failure CFG_FAIL-1-INCONS__CONFIG 763
LOS Loss of signal on ea st receive side ELOSRX-1-RX_EAST_LOS 764
LOF Loss of frame on east receive side ELFARX-1-RX_EAST_LFA 765
RAI Received an east remote alarm indication ERAIRX-1-RX_EAST_RAI 766
UNIDENTIFIED Loss of modulation on east receive side EIDLERX-1-EAST_LINE_IDLE 767
LOS Loss of signal on west receive side WLOSRX-2-RX_WEST_LOS 768
LOF Loss of frame on west receive side WLFARX-2-RX_WEST_LFA 769
RAI Received west remote alarm indication WRAIRX-2-RX_WEST_RAI 770
UNIDENTIFIED Loss of modulation on west receive side WIDLERX-2-WEST_LINE_IDLE 771
TX_DEGRADE Laser 1 power high T-LASPWR-1-POWER_HIGH 772
UNIDENTIFIED B1 errored seconds 15 mins high T-B1ES15M-1-HIGH 773
UNIDENTIFIED B1 severe errored seconds 15 mins high T-B1SES15M-1-HIGH 774
UNIDENTIFIED B1 background block errors 15 mins high T-B1BBE15M-1-HIGH 775
BER_SD B1 bit error rate 15 mins high T-B1BER15M-1-HIGH 776
UNIDENTIFIED B1 unavailable seconds 15 mins high T-B1UT15M-1-HIGH 777
UNIDENTIFIED B1 errored seconds 1 day high T-B1ES24H-1-HIGH 778
UNIDENTIFIED B1 severe errored seconds 1 day high T-B1SES24H-1-HIGH 779
UNIDENTIFIED B1 background block errors 1 day high T-B1BBE24H-1-HIGH 780
BER_SD B1 bit error rate 1 day high T-B1BER24H-1-HIGH 781
UNIDENTIFIED B1 unavailable seconds 1 day high T-B1UT24H-1-HIGH 782
UNIDENTIFIED FEC errored seconds 15 mins high T-FECES15M-1-HIGH 783
TableA-36 CTM GateWay/CORBA Mapping for the ONS 1580x (continued)
TMF Mapping NE Native Probable Cause NE Native Alarm Description
CTM
Internal
Index