A-25
Cisco Transport Manager Release 8.5 GateWay/CORBA User Guide and Programmer Manual
OL-14253-01
AppendixA Notifications, Fault Management, and Probable Cause Mapping
Probable Cause Mapping
A.5.4.2 ONS 15216 EDFA2
The following table lists the alarms for the ONS 15216 EDFA2 R2.3 and 2.4.
A.5.4.3 ONS 15216 EDFA3
The following table lists the alarms for the ONS 15216 EDFA3 R1.1.
TableA-19 CTM GateWay/CORBA Alarms for the ONS 15216 EDFA2 R2.3 and R2.4
TMF Mapping NE Native Probable Cause
CTM Internal Index (Not Reported
in the Notification)
UNIDENTIFIED Unknown alarm 8601
EQPT Excessive pump 1 current 8602
EQPT Excessive pump 2 current 8603
EQPT Excessive pump 1 laser temperature 8604
EQPT Excessive pump 2 laser temperature 8605
EQPT Loss of output power 8606
EQPT Loss of input power 8607
EQPT Gain out of range 8608
EQPT Case temperature out of range 8609
EQPT Power unit A failed 8610
EQPT Power unit B failed 8611
EQPT Database backup 8612
EQPT Database restore 8613
EQPT Cutover reset 8614
EQPT Software load 8615
EQPT Software reset 8616
TableA-20 CTM GateWay/CORBA Alarms for the ONS 15216 EDFA3 R1.1
TMF Mapping NE Native Probable Cause
CTM Internal Index (Not Reported in
the Notification)
UNIDENTIFIED Unknown alarm 8701
EQPT Gain degrade high 8702
EQPT Gain degrade low 8703
EQPT Laser 1 bias degrade 8704
EQPT Laser 2 bias degrade 8705
EQPT Laser 1 bias fail 8706
EQPT Laser 2 bias fail 8707
EQPT Power degrade high LINE1TX port 8708
EQPT Power degrade low LINE1TX port 8709
EQPT Power fail low LINE1RX port 8710