Appendix A Notifications, Fault Management, and Probable Cause Mapping

Probable Cause Mapping

Table A-31

CTM GateWay/CORBA Mapping for the ONS 15600 SONET R1.3.1 (continued)

 

 

 

 

 

 

 

 

 

 

CTM Internal Index (Not

TMF Mapping

 

NE Native Probable Cause

 

Reported in the Notification)

 

 

 

 

UNIDENTIFIED

TSC switched to alternate Ethernet port

 

17209

 

 

 

 

UNIDENTIFIED

Open I/O slot(s)

 

17210

 

 

 

 

UNIDENTIFIED

Software download failed

 

17211

 

 

 

 

UNIDENTIFIED

SNTP host failure

 

17212

 

 

 

 

UNIDENTIFIED

Equipment boot in progress

 

17213

 

 

 

 

 

A.5.15.2 ONS 15600 SONET R5.0

The following table lists the CTM GateWay/CORBA mapping for the ONS 15600 SONET R5.0.

Table A-32

CTM GateWay/CORBA Mapping for the ONS 15600 SONET R5.0

 

 

 

 

 

 

 

 

 

 

 

 

 

CTM Internal Index (Not

 

TMF Mapping

 

NE Native Probable Cause

Reported in the Notification)

 

 

 

 

 

 

 

 

 

EQPT

 

Alarms/events suppressed for this object

17501

 

 

 

 

 

 

 

 

 

 

 

UNIDENTIFIED

Audit log 100 percent full

17502

 

 

 

 

 

 

 

 

 

 

 

UNIDENTIFIED

Audit log 80 percent full

17503

 

 

 

 

 

 

 

 

 

 

 

UNIDENTIFIED

BLSR out of sync

17504

 

 

 

 

 

 

 

 

 

 

 

UNIDENTIFIED

BLSR multinode table update completed

17505

 

 

 

 

 

 

 

 

 

 

 

UNIDENTIFIED

TSC switched to alternate Ethernet port

17506

 

 

 

 

 

 

 

 

 

 

 

 

ENV

 

Failure detected external to the NE

17507

 

 

 

 

 

 

 

 

 

 

 

 

DCC_FAILURE

 

DCC channel loss

17508

 

 

 

 

 

 

 

 

 

 

 

 

DCC_FAILURE

 

SDCC termination failure

17509

 

 

 

 

 

 

 

 

 

 

 

 

AIS

 

Alarm indication signal

17510

 

 

 

 

 

 

 

 

 

 

 

 

AIS

 

Alarm indication signal—line

17511

 

 

 

 

 

 

 

 

 

 

 

 

AIS

 

Alarm indication signal—path

17512

 

 

 

 

 

 

 

 

 

 

 

 

FOP_APS

 

Byte failure

17513

 

 

 

 

 

 

 

 

 

 

 

 

FOP_APS

 

Protection switching channel match failure

17514

 

 

 

 

 

 

 

 

 

 

 

 

FOP_APS

 

Automatic protection switch mode mismatch

17515

 

 

 

 

 

 

 

 

 

 

 

 

FOP_APS

 

Connection loss

17516

 

 

 

 

 

 

 

 

 

 

 

 

FOP_APS

 

Default K byte

17517

 

 

 

 

 

 

 

 

 

 

 

 

FOP_APS

 

Far-end protection line failure

17518

 

 

 

 

 

 

 

 

 

 

 

 

ENV

 

APS channel—far-end protection line signal degrade

17519

 

 

 

 

 

 

 

 

 

 

 

 

FOP_APS

 

Improper APS code

17520

 

 

 

 

 

 

 

 

 

 

 

 

FOP_APS

 

Inconsistent APS code

17521

 

 

 

 

 

 

 

 

 

 

 

 

FOP_APS

 

Node ID mismatch

17522

 

 

 

 

 

 

 

 

 

 

 

UNIDENTIFIED

STS concatenation error

17523

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cisco Transport Manager Release 8.5 GateWay/CORBA User Guide and Programmer Manual

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OL-14253-01

 

 

 

 

A-103

 

 

 

 

 

 

 

Page 103
Image 103
Cisco Systems OL-14253-01 appendix 103