Appendix C RAID Controller Considerations
Mixing Drive Types in RAID Groups
Table
Table | Cisco UCS C22 Large Form Factor RAID Options |
| ||||
|
|
| Maximum | SCPM1 | RAID Levels |
|
Controller |
| Style | Drives | Supported | Required Cables | |
Embedded |
| Onboard | 4 SATA | No | 0, 1, 54, 10 | 4 drives: 1 |
MegaRAID2 |
|
| (default) or |
|
| |
|
|
| 4 SAS3 |
|
|
|
|
|
| internal |
|
|
|
|
|
|
|
|
|
|
LSI MegaRAID |
| PCIe | 4 internal | No | 0, 1, 10 | 4 drives: 1 |
|
|
|
|
|
| |
|
|
|
|
|
| |
LSI MegaRAID SAS | PCIe | 4 internal | No | 0, 1, 5, 10, 50 | 4 drives: 1 | |
|
|
|
|
| ||
|
|
|
|
|
| |
LSI MegaRAID SAS | PCIe | 4 internal | SCPM | 0, 1, 5, 6, 10, 50, 60 | 4 drives: 1 | |
|
|
|
|
|
| |
|
|
|
|
|
|
|
1.SCPM = SuperCap power module (the RAID backup unit).
2.The embedded RAID controller must be enabled in the BIOS.
3.Support for four SAS drives requires an optional SCU upgrade ROM module on the motherboard.
4.Embedded RAID 5 support requires an optional software key module.
Mixing Drive Types in RAID Groups
Table
Table
Mix of Drive Types |
|
in RAID Group | Allowed? |
|
|
SAS HDD + SATA HDD | Yes |
|
|
SAS SSD + SATA SSD | Yes |
|
|
HDD + SSD | No |
|
|
Best Practices For Mixing Drive Types in RAID Groups
For the best performance, follow these guidelines:
•Use either all SAS or all SATA drives in a RAID group.
•Use the same capacity for each drive in the RAID group.
•Never mix HDDs and SSDs in the same RAID group.
Cisco UCS C22 Server Installation and Service Guide
| ||
|