Chapter 3 Maintaining the Server

Installing or Replacing Server Components

Replacing a Software RAID Key Module

To remove and replace a software RAID key module, use the following procedure.

Step 1 Prepare the server for component installation:

a.Power off the server as described in Shutting Down and Powering Off the Server, page 3-6.

b.Slide the server out the front of the rack far enough so that you can remove the top cover. You might have to detach cables from the rear panel to provide clearance.

Caution If you cannot safely view and access the component, remove the server from the rack.

c.Remove the top cover as described in Removing and Replacing the Server Top Cover, page 3-7.Step 2 Remove the software RAID key module:

a.Locate the module on the motherboard (see Figure C-1).

b.Grasp the printed circuit board of the module and lift it from the header.

Note The module must have clearance from the retention clip on the header before the module can be pulled up. Open the retention clip, then pull up as shown in Figure 3-26.

Step 3 Install a new software RAID key module:

a.Align the module with the pins in the motherboard header.

b.Gently press down on the module until it is seated and the retention clip locks over the module.

Figure 3-26 Software RAID Key Module Retention Feature

1

2

3

2

1

4 303691

1

Printed circuit board on module

3

Motherboard header

 

 

 

 

2

Retention feature on motherboard header

4

Retention feature in installed position

 

 

 

 

 

 

 

 

For more information about using the module and embedded RAID, see Embedded RAID Controller, page C-5.

 

 

Cisco UCS C22 Server Installation and Service Guide

 

 

 

 

 

 

OL-26646-01

 

 

3-47

 

 

 

 

 

Page 85
Image 85
Cisco Systems OL-26646-01 manual Replacing a Software RAID Key Module, Software RAID Key Module Retention Feature