Appendix C RAID Controller Considerations
Supported RAID Controllers and Required Cables
Supported RAID Controllers and Required Cables
This server supports the RAID controller options and cable requirements shown in Table
Caution Do not mix controller types in the server. Do not use the embedded MegaRAID controller and a hardware RAID controller card at the same time. This is not supported and could result in data loss.
Note Dual controllers are not supported.
Note The cables in this section apply to both single- and
Table
Table | Cisco UCS C22 Small Form Factor RAID Options |
| ||||
|
|
| Maximum | SCPM1 | RAID Levels |
|
Controller |
| Style | Drives | Supported | Required Cables | |
Embedded |
| Onboard | 4 SATA | No | 0, 1, 54, 10 | 2 |
MegaRAID2 |
|
| (default) or |
|
| |
|
|
| 8 SAS3 |
|
|
|
|
|
| internal |
|
|
|
|
|
|
|
|
|
|
LSI MegaRAID |
| PCIe | 4 internal5 | No | 0, 1, 10 | 4 drives: 1 |
|
|
|
|
| ||
|
|
|
|
|
| |
LSI MegaRAID SAS | PCIe | 8 internal | No | 0, 1, 10 | 4 drives: 1 | |
|
|
|
|
| 8 drives: 2 | |
|
|
|
|
|
| |
|
|
|
|
|
| |
LSI MegaRAID SAS | PCIe | 8 internal | No | 0, 1, 5, 10, 50 | 4 drives: 1 | |
|
|
|
|
| 8 drives: 2 | |
|
|
|
|
|
| |
|
|
|
|
|
| |
LSI MegaRAID SAS | PCIe | 8 internal | SCPM | 0, 1, 5, 6, 10, 50, 60 | 4 drives: 1 | |
|
|
|
|
| 8 drives: 2 | |
|
|
|
|
|
| |
|
|
|
|
|
|
|
1.SCPM = SuperCap power module (the RAID backup unit).
2.The embedded RAID controller must be enabled in the BIOS.
3.Support for eight SAS drives requires an optional SCU upgrade ROM module on the motherboard.
4.Embedded RAID 5 support requires an optional software key module.
5.The
Cisco UCS C22 Server Installation and Service Guide
|
|
| |
|
|