9084-OM (V4.0) 9084 PRODUCT MA NUAL 3-39
Operating Instructions Troubleshooting
9084 Processing Error Troubleshooting

Table 3-5 provides 9084 processing troubleshooting information. If the 9084

card exhibits any of the symptoms listed in Table 3-5, foll ow the

troubleshooting instructions provided.

In the majority of cases, most errors are caus ed by simple errors where the

9084 is not appropriately set for the type of signal being received by the card.

Note: The error indications shown below are typical for the corresponding error con-

ditions listed. Other error indications not specified here may al so be displayed

on DashBoard and/or the 9084 card edge status indicators.

Note: Where errors are displayed on both the 9084 card and network remote con-

trols, the respective indicators and displays are individually descri bed in this

section.

Table 3-5 Troubleshooting Processing Errors by Symptom

Symptom Error/Condition Corrective Action

DashBoard shows Video
yellow icon and Input Invalid
message in 9084 Card Info
pane.
Card edge Input Format LEDs
show continuous cycling.
No video input present Make certain intended video source is
connected to appropriate 9084 card video input.
Make certain BNC cable connections between
frame Rear I/O Module for the card and signal
source are OK.
DashBoard shows Frame
Sync red icon and Reference
Invalid message in 9084 Card
Info pane.
Card edge red ERR indicator
illuminated.
Frame sync reference not
properly selected or not being
received
If external frame sync reference is not
intended to be used, make certain the
Framesync Enable selection list is set to Off
or Input Video as desired.
If external frame sync reference is intended to
be used, make certain selected external
frame sync reference is active on frame syn c
8310 frame bus. (External reference signals
Reference 1 and Reference 2 are distributed
to the 9084 and other cards via an 8310
frame bus.) Refer to Framesync function
submenu tab on page 3-22 for more
information.