Reclosers
Kyle® Form 5, Form 5 UDP, Form 5 DC NOVA | Service Information |
Installation and Operation Instructions |
Applicable to serial numbers above 3000 or beginning with CP57.
Figure 1. | 99001KM |
| |
Kyle® Form 5/UDP |
|
|
|
|
|
Safety Information . . . . . . . . . . . . . . . . . . . . . . . | . . 2 | Discrete Interface (DIF) Accessory . . . . . . . . . . . | . 23 | |
Product Information . . . . . . . . . . . . . . . . . . . . . . | . . 3 | Customer Connection Information . . . . . . . . . . . . | . 23 | |
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | . . 3 | Standard and UDP DIF Module 1 Inputs . . . . . . . | . 26 | |
ANSI Standards . . . . . . . . . . . . . . . . . . . . . . . . . | . . 3 | Standard and UDP DIF Module 1 Outputs . . . . . . | . 28 | |
Quality Standards . . . . . . . . . . . . . . . . . . . . . . . . | . . 3 | Standard and UDP Module 2 Inputs . . . . . . . . . . . | . 29 | |
Acceptance and Initial Inspection . . . . . . . . . . . . | . . 3 | Standard and UDP Module 2 Outputs . . . . . . . . . | . 30 | |
Handling and Storage . . . . . . . . . . . . . . . . . . . . . | . . 3 | Input Accuracy . . . . . . . . . . . . . . . . . . . . . . . . . . . | . 31 | |
Battery Replacement . . . . . . . . . . . . . . . . . . . . . | . . 3 | Installation Procedure . . . . . . . . . . . . . . . . . . . . . | . 32 | |
Control Power . . . . . . . . . . . . . . . . . . . . . . . . . . . | . . 3 | Initial Programming Prior to Installation . . . . . . . . | . 32 | |
Initializing the Control . . . . . . . . . . . . . . . . . . . . . | . . 4 | Control / Recloser Compatibility . . . . . . . . . . . . . . | . 32 | |
Form 5 Control Description . . . . . . . . . . . . . . . . | . . 5 | Control Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . | . 32 | |
Recloser Interface (RIF) Module . . . . . . . . . . . . | . . 6 | Mounting the Control . . . . . . . . . . . . . . . . . . . . . . | . 33 | |
Central Processing Unit (CPU) Module . . . . . . . | . . 6 | Grounding the Control . . . . . . . . . . . . . . . . . . . . . | . 34 | |
Discrete Interface (DIF) Module . . . . . . . . . . . . . | . . 6 | Customer Connections for AC Power . . . . . . . . . . | . 38 | |
Power Supply Module . . . . . . . . . . . . . . . . . . . . . | . . 6 | Customer Connections for Metering . . . . . . . . . . . | . 38 | |
Form 5 Control Operator Panel . . . . . . . . . . . . . | . . 7 | Before Placing Control and Recloser into Service | . 42 | |
Battery Test Procedure . . . . . . . . . . . . . . . . . . . . | . . 14 | Testing and Troubleshooting . . . . . . . . . . . . . . . | . 43 | |
Control Features . . . . . . . . . . . . . . . . . . . . . . . . . | . . 14 | Testing an Installed Control . . . . . . . . . . . . . . . . . | . 43 | |
Communications . . . . . . . . . . . . . . . . . . . . . . . . . | . . 19 | Testing with Type MET Tester . . . . . . . . . . . . . . . | . 43 | |
Auxiliary Power for Accessories . . . . . . . . . . . . | . . 20 | Closing the Recloser During Testing . . . . . . . . . . | . 44 | |
Recloser Interface (RIF) Module Configuration | . . 20 | Form 5 Control Default Test Procedure . . . . . . . | . 47 | |
Form 5 Universal Device Protection (UDP) |
| Remove the Control from Service . . . . . . . . . . . . | . 55 | |
Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | . . 21 | Return the Control to Service . . . . . . . . . . . . . . | . 55 | |
Form 5 DC NOVA Control . . . . . . . . . . . . . . . . | . . 22 | |||
Additional Information . . . . . . . . . . . . . . . . . . . . | . 56 | |||
|
| |||
|
|
|
| |
November 2001 • Supersedes 1/01 |
|
| 1 |
Printed in USA