InelliCarb Training Manual
C.Initial
NOTE:If the carbonator Pump and Motor does not cycle (turn on and off) properly, check that the probe harness connector and ground lead are secured to the carbonator tank connection points.
D.If service is required on Ice Drink units, it will be necessary to lower the beverage valve panel to gain access to the probe and ground connection. Remove the lower front panel (2 screws) from the cabinet and the ice chute cover (“snap” fit). Remove the 6 screws that secure the beverage panel to the cabinet. The panel can now be moved downward due to the flexibility of the beverage tubing to expose the carbonator tank connections.
Carbonator Relief Valve Locations
The carbonator tank is located behind the splash panel, on the right side of the dispenser. You will need to pull the relief valves to purge air from the system after the CO2 supply has been hooked up. Failure to do this will cause low carbonation volume and popping of the relief valves.
Agitator
Motor
Relief |
| Carbonator |
Valve Ring |
| |
| Tank | |
|
|
Carbonator
Tank Relief
Valve
FIGURE 6 | FIGURE 7 |
2.Dispenser
Ice Drink Model ED175BCH (Lower Front Panel Removed)
Insulated Cold Plate
Cover & Carbonator
Tank Assembly
Total Flex Manifold
(with insulation)
Total Flex Manifold
Cold Plate Inlets(insulation removed) (3/8 Barb)
Carb. Tank Liquid |
|
| Carb Tank CO2 | ||
|
|
|
| ||
|
| Supply Line | |||
Level Probe Harness |
|
|
| ||
|
|
|
|
|
FIGURE 8
© 2004, IMI Cornelius Inc. | - 5 - | Publication Number: TP01071 |