Training Manual
INTELLICARB
Release Date April 29 Publication Number TP01071 Revision Date NA
Revision A
INTELLICARB TRAINING MANUAL
TABLE OF CONTENTS
Introduction
Mechanical Section
Post-Mix Valve Section
Troubleshooting
Electrical Section
IntelliCarb Training Manual
INTRODUCTION
UNIT DESCRIPTION
THEORY OF OPERATION
DESCRIPTION
SPECIFICATIONS
REQUIREMENTS
DELIVERY INSPECTION AND UNPACKING
Dimensions CO2 Operating Pressure
INSTALLATION
Carbonator Time Out Reset Switch
CORNELIUS INTELLICARB CARBONATOR ASSEMBLY
Drains
Carbonator Relief Valve Locations
Ice Drink Model ED175BCH Lower Front Panel Removed
Ice Drink Model ED150/175/300 Coldplate Cover
Ice Drink Model ED200/250 Coldplate Cover
Total Flex Manifold Insulation Removed
Liquid Level Probe
NOTE Carbonator troubleshooting procedure located on page
6. Check list for proper “finished” drink carbonation
Adjustment
MECHANICAL SECTION
GATE RESTRICTOR PLATE
ICE DIVERTER KIT
To Remove Agitators For Cleaning 300 shown
REMOVAL AND REPLACEMENT OF AGITATORS
NOTE All other models have only one agitation Assembly
Dimensions & Capacities
POST-MIX VALVE SECTION
Water
SET-UP INSTRUCTIONS
Notch in piston
Syrup/Concentrate
Adjusting Flow Rates
NOTE Always adjust water within its range
Water Flow Rates At Selected Ratios
Setting Ratios
NOTE Try raising the pressure on the pump before cleaning
NOTE Valve troubleshooting information is available on page
SHURFLO
SHURFLOW OVERVIEW
NOTE Shurflow Troubleshooting information available on page
SHURFLOW INSTALLATION
START-UP PROCEDURE
TYPICAL INSTALLATION
PLUMBING
FIGURE 21. Typical Installation
2004, IMI Cornelius Inc
PLUMBING LAYOUT
FIGURE 22. Plumbing Layout
FLOW DIAGRAM 1XX SIX FLAVOR MODEL
Flow Diagram
1xx Six Flavor Model
2004, IMI Cornelius Inc
INSTALL FOR
Eight Flavor Models
Publication Number TP01071
2004, IMI Cornelius Inc
FLOW DIAGRAM 2XX EIGHT FLAVOR MODELS
FIGURE 25. Flow Diagram
2xx Eight Flavor Models
2004, IMI Cornelius Inc
FLOW DIAGRAM 2XX TEN FLAVOR MODELS
FIGURE 26. Flow Diagram 2xx Ten Flavor Models
Publication Number TP01071
2004, IMI Cornelius Inc
FLOW DIAGRAM 300 TWELVE F
LAVOR MODELS
Diagram
Flow
ELECTRICAL SECTION
Control Box Single Transformer Will Power
One Transformer Powers the Left Bank
and the Other Powers the Right Bank
CARBONATOR WIRING DIAGRAM
Time Out Selection Pins. 7min/3 min/Disabled Move Jumper to Select
RESET CONNECTIONS
2004, IMI Cornelius Inc
SERVICE INFORMATION
Wiring Diagram
DA NGER
EL ECTRIC SHOCK HA ZA RD. DISCONNECT
SCHEMATIC
FIGURE 32. Schematic
2004, IMI Cornelius Inc
Publication Number TP01071
WIRING DIAGRAM 2XX 120V MODEL
FIGURE 33. Wiring Diagram
SERVICE INFORMATION
POWER BEFORE SERVICING UNIT
WIRING DIAGRAM
Wiring Diagram
2xx 220/240V Models
2004, IMI Cornelius Inc
WIRING DIAGRAM 2XX 220/240V MODELS
FIGURE 35. Wiring Diagram 2xx 220/240V Models
Publication Number TP01071
2004, IMI Cornelius Inc
WIRING DIAGRAM
220/240V MODELS
SERVICE INFORMATION
DANGER! ELECTRIC SHOCK HAZARD. DISCONNECT POWER BEFORE SERVICING UNIT
WIRING DIAGRAM
SERVICE INFORMATION
DANGER ELECTRIC SHOCK HAZARD. DISCONNECT POWER BEFORE SERVICING UNIT
Wiring Diagram
SCHEMATIC 300 120V MODELS
FIGURE 38. Schematic 300 120V Models
TIMER
2004, IMI Cornelius Inc
SCHEMATIC 300 220/240V MODELS
FIGURE 39. Schematic 300 220/240V Models
Publication Number TP01071
2004, IMI Cornelius Inc
TROUBLESHOOTING
SHURFLOW TROUBLESHOOTING
Pumping Capability
MAXIMUM HORIZONTAL TUBING LENGTHS BY VISCOSITY
Pumps in Series for Long Distances
Pump Sanitizing / Winterizing
Pump Troubleshooting
DOES NOT OPERATE / GAS APPLIED / DISPENSER VALVE OPEN
OPERATES BUT WILL NOT PRIME / DISPENSER VALVE OPEN
DOES NOT ACHIEVE SOLD-OUT WITH EMPTY B-I-B
DISPENSER TROUBLESHOOTING
Trouble
Probable Cause
Remedy
VALVE TROUBLESHOOTING
Excess Foam
Problem excess foam
Temp ? below Remove nozzle Clean ? no Clean Problem corrected
Off Taste
Problem off taste Remove nozzle Clean ? no Clean Problem corrected
Off Taste
Publication Number TP01071
Valve Stuck Open
Problem valve
Check for power at solenoid
Valve Stuck Open
No Product
Problem no product Check solenoid visually Working ? no
Power ? no Check switch Problem corrected
No Product
CARBONATOR TROUBLESHOOTING
Solid State Carbonator Level Control
Trouble
Probable Cause
IMI Cornelius Inc